4.
Remove the wire link between the terminals (B) and (C) on terminal block -
X37 (2).
5.
Connect the terminals (A), (B), (C) and (D) of terminal block -X37 (2) to the
energy optimization system.
Terminal
Combi oven
Energy optimization
system
A
Phase, when combi oven is on
-
B
Phase, when combi oven heat-
ing element is on
Switching relay
C
Heater enable, B and C must
be connected by switching re-
lay in the energy optimization
system in order to enable heat-
ing
Switching relay
D
Neutral
-
6.
Refit the side panel on the combi oven.
7.
Put the combi oven and energy optimization system into operation.
6.1.4 Connecting the signal tower
Purpose of a signal tower
A signal tower that is electronically connected to the combi oven indicates the current operating status of your combi oven visually,
using three indicator lamps (green, yellow, red), and acoustically. This indicating device provides a signal that can be seen and
heard from far away.
Accessories required
The signal tower is supplied with the following original accessories, which you will need in order to connect the signal tower to the
combi oven:
■
Connecting cable (approx. length 10 m) with M12 female connector
■
DN 50 diaphragm grommet
In addition you will need the following equipment:
■
Cable ties
6 Installation
Installation manual
45