6.10
6.20
10.10
10.20
Protective earth current
[mA]
~7.5
~7.5
~7.5
~7.5
Recommended conductor cross-section for wires laid uncovered in
air up to 5 m in length.
[mm
2
]
5G4
5G6
5G6
5G16
Residual-current device
Type
A/B
A/B
A/B
A/B
C4 GB (single-phase FC)
6.10
6.20
10.10
10.20
1N~ 220V 60Hz (1/N/PE)
Rated power consumption
[kW]
0.6
0.6
0.6
0.6
Convection power
[kW]
0.1
0.1
0.1
0.1
Steam power
[kW]
0.1
0.1
0.1
0.1
Motor power
[kW]
0.35
0.35
0.35
0.35
Rated current
[A]
2.7
2.7
2.7
2.7
Fuse rating
[A]
16
16
16
16
Residual current
[mA]
7.9
-
-
-
Protective earth current
[mA]
28.0
-
-
-
Recommended conductor cross-section for wires laid uncovered in
air up to 5 m in length.
[mm
2
]
3G2.5
3G2.5
3G2.5
3G2.5
Residual-current device
Type
A/B
A/B
A/B
A/B
C4 GS (single-phase FC)
6.10
6.20
10.10
10.20
1N~ 220V 60Hz (1/N/PE)
Rated power consumption
[kW]
0.5
0.5
0.5
0.5
Convection power
[kW]
0.1
0.1
0.1
0.1
Motor power
[kW]
0.35
0.35
0.35
0.35
Rated current
[A]
2.3
2.3
2.3
2.3
Fuse rating
[A]
16
16
16
16
Residual current
[mA]
7.0
7.0
6.9
-
Protective earth current
[mA]
28.0
33.0
-
-
Recommended conductor cross-section for wires laid uncovered in
air up to 5 m in length.
[mm
2
]
3G2.5
3G2.5
3G2.5
3G2.5
Residual-current device
Type
A/B
A/B
A/B
A/B
9.7 Electrical supply, Mexico/Nicaragua
C4 GB (single-phase FC)
6.10
6.20
10.10
10.20
1N~ 120V 60Hz
Rated power consumption
[kW]
0.6
0.6
0.6
0.6
Convection power
[kW]
0.1
0.1
0.1
0.1
Steam power
[kW]
0.1
0.1
0.1
0.1
Motor power
[kW]
0.4
0.4
0.4
0.4
Rated current
[A]
5.7
5.7
5.7
5.7
Fuse rating
[A]
16
16
16
16
Residual current
[mA]
2.4
-
10.6
-
Protective earth current
[mA]
-
-
1.6
-
Recommended conductor cross-section for wires laid uncovered in
air up to 5 m in length.
[mm
2
]
3G2.5
3G2.5
3G2.5
3G2.5
Residual-current device
Type
A/B
A/B
A/B
A/B
9 Technical data
Installation manual
71