Rated power consumption
[kW]
10.9
19.3
19.3
33.4
Convection power
[kW]
10.5
18.9
18.9
33.0
Steam power
[kW]
9.0
18.0
18.0
27.0
Motor power
[kW]
0.35
0.35
0.35
0.35
Rated current
[A]
31.5
55.8
55.8
96.6
Fuse rating
[A]
35
63
63
100
Residual current
[mA]
-
-
-
-
Protective earth current
[mA]
-
-
-
-
Recommended conductor cross-section for wires laid uncovered in
air up to 5 m in length.
[mm
2
]
4G6
4G16
4G16
4G35
Residual-current device
Type
A/B
A/B
A/B
A/B
C4 ES (single-phase FC)
6.10
6.20
10.10
10.20
3~ 200 V 50/60 Hz (3/PE)
Rated power consumption
[kW]
10.9
19.3
19.3
33.4
Convection power
[kW]
10.5
18.9
18.9
33.0
Motor power
[kW]
0.35
0.35
0.35
0.35
Rated current
[A]
31.5
55.8
55.8
96.6
Fuse rating
[A]
35
63
63
100
Residual current
[mA]
-
-
-
-
Protective earth current
[mA]
-
-
-
-
Recommended conductor cross-section for wires laid uncovered in
air up to 5 m in length.
[mm
2
]
4G6
4G16
4G16
4G35
Residual-current device
Type
A/B
A/B
A/B
A/B
9.6 Electrical supply, Korea
C4 EB/ES (single-phase FC)
6.10
6.20
10.10
10.20
3~ 220 V 60 Hz (3/PE)
Rated power consumption
[kW]
10.2
17.7
17.7
30.6
Convection power
[kW]
9.6
17.3
17.3
30.2
Steam power (EB only)
[kW]
8.2
16.5
16.5
24.7
Motor power
[kW]
0.35
0.35
0.35
0.35
Rated current
[A]
26.8
46.5
46.5
80.3
Fuse rating
[A]
35
50
50
100
Residual current
[mA]
-
-
-
-
Protective earth current
[mA]
-
-
-
-
Recommended conductor cross-section for wires laid uncovered in
air up to 5 m in length.
[mm
2
]
4G6
4G10
4G16
4G35
Residual-current device
Type
A/B
A/B
A/B
A/B
3N~ 380 V 60 Hz (3/N/PE)
Rated power consumption
[kW]
10.1
17.6
17.6
30.5
Convection power
[kW]
9.6
17.2
17.2
30.1
Steam power (EB only)
[kW]
8.2
16.3
16.3
24.5
Motor power
[kW]
0.35
0.35
0.35
0.35
Rated current
[A]
15.4
26.7
26.7
46.3
Fuse rating
[A]
16
32
32
50
Residual current
[mA]
~7.5
~7.5
~7.5
~7.5
9 Technical data
Installation manual
70