
No.
Guard or safety device
Function
Check
7
(installed by
the customer)
Disconnector
Used to de-energize the unit during
cleaning, repairs, and maintenance
work, as well as in hazardous situa-
tions
The operator does not need to check
anything.
8
(installed by
the customer)
Gas shut-off device
Used to disconnect the unit from the
gas supply during cleaning, repair,
and maintenance work, as well as in
hazardous situations
The operator does not need to check
anything.
Safety measures
The following measures will contribute to greater safety:
Measure
Function
Check
Unit door solenoid switch
(electrical door sensor)
■
Stops/turns off the following when the unit
door is opened:
■
Fan (will stop after a few seconds)
■
Heating element
■
Cleaning agent spraying in the fully au-
tomatic oven cleaning process
■
Prompts the user to close the unit door
Test the door solenoid switch with the combi
oven at a low temperature
Procedure:
■
Fully open the unit door
■
Press Start
Result:
The motor must not start running.
Resuming after a power out-
age if there was cleaning
agent inside the unit when
the power went out
■
Starts the fully automatic or semi-automat-
ic oven cleaning process again, from a de-
fined state, after a power outage
None
3 For Your Safety
Operating Manual
30