Preface

Symbol Stipulations

The meanings of the following symbols which may appear in this manual

Symbols

Meanings

Indicates that there is a high level of potential danger, if not
avoided, it may cause casualties or serious injures.
Indicates that there is a medium or low level of potential
danger. If not avoided, it may cause minor or moderate
injury to personnel.
Indicates potential risks. If you ignore the information, it
may cause equipment damage, data loss, equipment
performance degradation, or unpredictable results.
Indicates that it can help you solve a problem or save your
time.
Indicates that it is the additional information of the main
text, which emphasizes and supplements the main text.

Revision Records

Version No.

Revision Content

Release Date

V1.0.0

First Release

2022.02

Safety Instructions

The following is the correct methods of using the product, in order to prevent danger, prevent
property damage, etc., please read this manual carefully before using the equipment and strictly
follow it during use. Please keep the manual properly after reading.

Operating Environment Requirements

Please transport, use and store the device within the allowable humidity and temperature range.
Please do not let any liquid flow into the device.
Please install the device in a well-ventilated place, and do not block the vents of the device.
Please do not press hard, vibrate violently or soak the equipment.
Please use the factory packaging or materials of the same quality when shipping the equipment.
It is recommended to ground via the grounding hole on the device to improve the reliability.

Operation and Maintenance Requirements

Please do not disassemble the device privately.
Please use the accessories or attachments of the manufacturer for installation and maintenance by
professional service personnel.
Please do not provide two or more power supply methods to the device at the same time, otherwise
the device may be damaged.
The self-contained boom is not allowed to be lengthened or cut off, and it is also not allowed to add
weight to the boom privately.

Summary of Contents for DC24V

Page 1: ...I DC Variable Frequency 3D Barrier Gate SCB02 DC24V Manual V1 0 1...

Page 2: ...ead this manual carefully before using the equipment and strictly follow it during use Please keep the manual properly after reading Operating Environment Requirements Please transport use and store t...

Page 3: ...anations 4 4 2 Controller Parameter Setting of Master Motor 6 4 3 Regular Menu Command List of Master Motor 6 4 4 Advanced Menu Command List of Master Motor 12 4 5 Controller Parameter Setting of Slav...

Page 4: ...le to stop at any position in three dimensional space no longer limited height problem 1 1 7 Double protection one drive failure will not affect the other drive and the barrier gate can still operate...

Page 5: ...4 Motor power up and down power 180W horizontal power 60W 1 2 5 Relative Humidity 30 80 No condensation 1 2 6 Distance of remote control L 30M 1 2 7 Running Speed 0 3 seconds MAX 1 2 8 MTBF 8 000 000...

Page 6: ...on the ground with 4 sets M16 150 expansion bolts At the location where the cabinet is installed the barrier foundation should be made according to the site conditions and the cast in place foundatio...

Page 7: ...tem Explanation Wire Control Interface This interface is available for parking system also available for external controller to control barrier gate UP Short circuit UP and GND Down Short circuit Down...

Page 8: ...modes via option 4 of the advanced menu DC12V Power Output Provide 1A current output available for radar or small light strips Interface for R G lights Available to connect with R G lights to indicate...

Page 9: ...used to display the information of the slave motor of the barrier gate such as the working status parameters menu items 4 2 Controller Parameter Setting of Master Motor Long press button for 2 second...

Page 10: ...he angle at which the boom enters a low speed area in the opening process if the boom shakes after it is opened in place users can reduce this value 1 5 End Speed 8 1 50 6 8 The minimum speed at which...

Page 11: ...ter it is closed in place users can increase this value 2 4 Angle of Low speed Area 0 0 45 0 The angle at which the boom enters a low speed area in the closing process if the boom shakes after it is c...

Page 12: ...ed that chapter 1 5 set until it is opened in place If the value is 90 the function is invalid If the boom shakes after it is opened in place users can reduce this value appropriately Chapter 2 4 has...

Page 13: ...when the barrier gate is installed under an eaves please select the Find down limit only mode 4 2 Manual learning f up and down Limit None operate according to the prompts on the screen In manual mod...

Page 14: ...clear code Press the Setting button to invert the color of the symbol on the screen and press and at the same time to clear the code of all remote controllers 4 3 6 RS485 setting Sub menu Defaults Ran...

Page 15: ...e sensitivity is the smaller it is the higher the sensitivity Unit millisecond 4 3 10 Restore factory defaults press the setting button to invert the color of the symbol on the screen and press and at...

Page 16: ...ier gate closes at down limit position users can increase this value appropriately to get some force 3 2 Motor type 129 Rotates Forward 129 Forward Reverse CB03 Forward Reverse It is used for matching...

Page 17: ...sed when boom falls down the signal during boom falling down and boom at down limit position can be used as R G light signal or used for detecting the barrier gate running status 4 4 5 Buffer time for...

Page 18: ...op detector to prevent vehicle from being followed by other vehicles and can also prevent the misoperation of the loop detector from triggering the opening of the barrier gate The default value is 5 d...

Page 19: ...r the boom up speed F 01 Boom Down Speed 100 15 100 90 100 The smaller the value the faster the boom down speed F 02 Boom Up deceleration position 40 10 80 35 45 The angle at which the boom up starts...

Page 20: ...xplanation F 02 Boom up deceleration position It is used to set the starting position of deceleration in the process of boom lifting up The unit of angle is 0 degrees when the barrier gate is in the h...

Page 21: ...s speed when boom lifts up If the parameter is set too large the gate lever will shake when it is opened F 07 End speed of boom down The speed for boom moves to down limit The boom will end moving at...

Page 22: ...te control learning This item is used for the remote control learning of the 3 wire radio receiver of the slave motor It is only used when the main motor fails and the slave motor is used to control t...

Page 23: ...misoperation it needs to set a specific value before pressing button to complete the operation 5 Clear all learned remote controller of the 3 wire radio receiver of the slave motor 10 Restore factory...

Page 24: ...ined by F 07 the larger the value the greater the force And the value needs to be set properly and the boom can be closed to limit position without swinging is ok Set the pressure of the boom holder o...

Page 25: ...s a lot at up limit position Opening speed in up limit position is relatively large Reduce the value of 1 5 in regular menu of the main motor Opening deceleration angle is large Reduce the value of 1...

Page 26: ...The closing deceleration angle of the slave motor F 03 is too small Increase the value of F 03 Boom down limit position speed of the slave motor F 07 is too large Reduce the value of F 07 6 Warranty a...

Page 27: ...t 7 4 Remote control distance will be shortened or not work in cases like big object screening battery exhausting extreme weathers 8 Packing List Name Specification Quantity Unit Application Screw Nut...