17
closing to limit
F-09
Swing range
adjustment of
horizontally
opening to limit
40
1-600+ 40-50
Adjustment the vertical position of
the barrier gate
F-10
Delay
auto-close time
1
0-255
1
Auto drop off time when no car
passes, unit: second
F-11
Locking time of
opening to up
limit
5
0-255
5
Lock the gate for a period of time
after opening in place, unit: second
F-12
Locking time of
closing to down
limit
0
0-255
5
Lock the gate for a period of time
after closing in place, unit: second
F-13
Power-on
self-learning
speed
15
10-80
12-20
Find up and down limit at this speed
F-14
Remote control
learning
0
0-30
Learning remote control
F-15
Sensitivity of
Auto-reversing
on obstruction
5
1-40
3-10
Obstruction response time, unit: 0.05
second
4.7. "Regular Menu" Command Explanation:
F-02 Boom up deceleration position
It is used to set the starting position of deceleration in the process of boom lifting up.
The unit of angle is 0 degrees when the barrier gate is in the horizontal position and
90 degrees when it is in the vertical position. This parameter indicates that the barrier
will start to decelerate when the boom lifts up to this angle. If the boom shakes when
lifting to up limit position, this parameter can be reduced.
F-03 Boom down deceleration position
It is used to set the starting position of deceleration in the process of boom falling
down. The unit of angle is 0 degrees when the barrier gate is in the horizontal
position and 90 degrees when it is in the vertical position. This parameter indicates
that the barrier gate will start to decelerate when the boom falls down to this angle. If
the boom shakes when falling to down limit position, this parameter can be increased.
F-04 Low-speed running angle of boom up