7
1.2 Opening Speed
100
15-100
90-100
The
bigger
the
value, the faster the
opening speed
1.3 Deceleration Angle
65
10-80
60-70
The angle at which
deceleration begins
in
the
opening
process; if the boom
shakes after it is
opened in place,
users can reduce this
value.
1.4 Angle of Low-speed
Area
90
45-90
90
The angle at which
the boom enters a
low-speed area in
the opening process;
if the boom shakes
after it is opened in
place, users can
reduce this value.
1.5 End Speed
8
1-50
6-8
The minimum speed
at which the barrier
gate is opened in
place; if the boom
shakes after it is
opened in place,
users can reduce this
value.
1.6 Learning Speed
25
10-50
25
The speed at which
the the barrier gate
begins to learn the
up limit position
after the power is
turned on for the
first time.
4.3.2. Closing operation parameters