2.1 Acceleration Time
1
1-20
1-3
The smaller the
value, the faster the
speed
2.2 Closing Speed
100
15-100
90-100
The
bigger
the
value, the faster the
opening speed
2.3 Deceleration Angle
35
10-80
33-38
The angle at which
deceleration begins
in
the
closing
process; if the boom
shakes after it is
closed in place,
users can increase
this value.
2.4 Angle of Low-speed
Area
0
0-45
0
The angle at which
the boom enters a
low-speed area in
the closing process;
if the boom shakes
after it is closed in
place, users can
reduce this value.
2.5 End Speed
4
1-50
2-5
The minimum speed
at which the barrier
gate is closed in
place; if the boom
shakes after it is
closed in place,
users can reduce this
value.
2.6 Learning Speed
25
10-50
25
The speed at which
the the barrier gate
begins to learn the
down limit position
after the power is