9
turned on for the
first time.
1.3 The Deceleration Angle
It is used to set the angle at which deceleration begins in the opening process. The
angle is 0 degree when the barrier gate is opened in place(in horizontal position)
and 90 degrees when it is closed in place(in vertical position). This parameter
indicates that deceleration begins when the barrier gate is opened to this angle. If
the boom shakes after it is opened in place, users can reduce this value. (Chapter
2.3 has the similar operation)
1.4 The Angle of Low-speed Area
It is used to set a low-speed area in the opening process. When the opening angle
reaches the set angle, the barrier gate will run at the end speed that chapter 1.5 set
until it is opened in place. If the value is 90, the function is invalid. If the boom
shakes after it is opened in place, users can reduce this value appropriately.
(Chapter 2.4 has the similar operation)
1.5 The End Speed
This is the minimum speed at which the barrier gate is opened in place. The barrier
gate will run at the this speed until it is opened in place. If the parameter is set too
large, the boom will shake when it is opened in place. (Chapter 2.5 has the similar
operation)
4.3.3. Quick operation parameter
Sub-menu
Model Type
Remarks
Auto setting of opening and closing
operating parameter according to
different models
SCB02
Quickly set parameters
according to different
models
Notice:
this device can quickly set the opening and closing operating parameters
according to the model types, which shorten the debugging time. If the effect is still