18
This parameter sets a low-speed uniform speed zone during the opening process.
During the boom up process, after reaching this angle set by F-04, it will run at the
boom up speed set by F-06 until it is completely closed. If this parameter is set to 90,
this function is invalid. If the boom shakes when lifting to up limit position, this
parameter can be reduced.
F-05 Low-speed running angle of boom down
This parameter sets a low-speed uniform speed zone during the closing process.
During the boom down process, after reaching this angle, it will run at the boom
down speed set by F-07 until it is completely closed. If this parameter is set to 0, this
function is invalid. If the boom shakes when falling to down limit position, this
parameter can be increased.
F-06 End speed of boom up
The speed for boom moves to up limit. The boom will end moving at this speed when
boom lifts up. If the parameter is set too large, the gate lever will shake when it is
opened.
F-07 End speed of boom down
The speed for boom moves to down limit. The boom will end moving at this speed
when boom falls down. If this parameter is set too large, the gate lever will shake
when it is closed.
F-08 Position adjustment of horizontally closing to limit
If the position of horizontally closing to limit is deviation, this parameter can be used
to fine-tune. Please see the left photo below.
F-09 Swing range adjustment of horizontally opening to limit
You can fine-tune this parameter to adjust the swing range of horizontally opening to
limit. Please see the right photo above.
F-10 Delay auto-closing time
After the barrier gate is opened, if the time set by this parameter passes and the
ground sensor does not detect the passing of the vehicle, the barrier gate will
automatically close. That means, the horizontal motor will swing to closing position
automatically after opening to limit position. If set to 0, the barrier gate will remain