12
second.
Notice:
when no loop detector or radar is installed, this function can be used for
auto-closing. It can also be used with counting function to prevent the situation that
the barrier gate is not closed because of over-counting.
4.3.8. Counting function
Defaults
Range
Remarks
OFF
OFF-ON
store the times of opening signal, and the barrier
gate will be auto closed when the number of the
leaving vehicles is the same as the number of the
opening signal.
4.3.9. Sensitivity of auto-reversing on obstacle
Defaults
Range
Remarks
100
50-400
Auto-reversing response time: the bigger it is, the
lower the sensitivity is; the smaller it is, the higher
the sensitivity. Unit: millisecond.
4.3.10. Restore factory defaults:
press the setting button to invert the color of the +-
symbol on the screen, and press ▲ and ▼ at the same time to restore the default
values of all parameters.
-------------------------------------------------------------------------------------------------------
4.4. "Advanced Menu" Command List of Master Motor
"Advanced Menu"
access method: simultaneously long press the "
三
" and "■"
button for 2 seconds to enter the menu setting status.
Advanced menu is for professional technician, general users should use it with
caution!
4.4.1. Auto-aging test
Sub-menu
Defaults Range
Remarks
1.1 Time Interval
OFF
0-5, 0 is
OFF
Time interval for auto aging test; unit:
second.
1.2 Boom up
angle
0
0-90
Boom up angle after switching from off to
on. If the value is odd, it will keep
switching from off to on all the time, if the