上海维宏电子科技股份有限公司
SHANGHAI WEIHONG ELECTRONIC TECHNOLOGY CO., LTD
.
55
/
116
4.4.1 Serious Electric Interference
Reason
The position of the servo drive creates some interference.
The shielding layer has been damaged or entangled on the external iron frame.
There is no conductivity between the No.4 pin of the M16 three-core aviation plug
towline cable and the amplifier.
There is gap between the follow-up amplifier and the machine.
The RF cable is damaged.
The machine is poorly grounded.
Solution
Ensure that the servo drive, Lambda 5E controller, and EX33A extension terminal
board are grounded properly.
If there is poor contact, construct paling again.
Ensure that the cable shielding layer is intact.
If not, replace the shielding layer.
Ensure conductivity between the No.4 pin of the M16 three-core aviation plug
towline cable and the amplifier.
If not, replace the cable.
Ensure that the follow-up amplifier is entirely in close contact with the machine.
If not, before installing the amplifier, use a piece of abrasive paper to remove the
oxidized layer from the contact surface.
Use a multimeter to check the RF cable.
If the RF cable is not working, replace it.
Ensure that the machine is grounded properly.
4.4.2 Capacitance is Not Zero when Touching the Material
Reason
There is no conductivity or the conductivity is poor between the material and
machine.
The material has insulative objects such as rusts or paint in the calibration area.
Solution
Follow the steps below to help troubleshoot:
1. In
Step
mode, slowly lower the cutter to make it touch the material and check the
capacitance again.
2. Set
Touch Part Capacitance
to a value larger than the capacitance currently
displayed.
4.4.3 Cutter Continues Lowering After Touching the Material During Calibration
Reason
After the cutter nozzle touches the material, the system receives no signal from the follow-
up amplifier that indicates zero capacitance.
Solution
See Capacitance is Not Zero when Touching the Material.
4.4.4 Actual Follow Height Differs from Setting
Reason
Summary of Contents for LS6000M
Page 75: ...SHANGHAI WEIHONG ELECTRONIC TECHNOLOGY CO LTD 72 116 With brake lines 50P HD plug...
Page 76: ...SHANGHAI WEIHONG ELECTRONIC TECHNOLOGY CO LTD 73 116 Without brake lines 50P HD plug...
Page 78: ...SHANGHAI WEIHONG ELECTRONIC TECHNOLOGY CO LTD 75 116 One to two...
Page 81: ...SHANGHAI WEIHONG ELECTRONIC TECHNOLOGY CO LTD 78 116 Fuji alpha5 plus axis X Y1 Y2...
Page 83: ...SHANGHAI WEIHONG ELECTRONIC TECHNOLOGY CO LTD 80 116 Delta ASDA B...
Page 84: ...SHANGHAI WEIHONG ELECTRONIC TECHNOLOGY CO LTD 81 116 Delta ASDA B one to two...
Page 86: ...SHANGHAI WEIHONG ELECTRONIC TECHNOLOGY CO LTD 83 116 MR JE with brake cable...
Page 87: ...SHANGHAI WEIHONG ELECTRONIC TECHNOLOGY CO LTD 84 116...
Page 91: ...SHANGHAI WEIHONG ELECTRONIC TECHNOLOGY CO LTD 88 116 ESDA...
Page 93: ...SHANGHAI WEIHONG ELECTRONIC TECHNOLOGY CO LTD 90 116 R series...
Page 96: ...SHANGHAI WEIHONG ELECTRONIC TECHNOLOGY CO LTD 93 116 With brake lines 50P HD plug...
Page 97: ...SHANGHAI WEIHONG ELECTRONIC TECHNOLOGY CO LTD 94 116 Without brake lines 44P interface...
Page 105: ...SHANGHAI WEIHONG ELECTRONIC TECHNOLOGY CO LTD 102 116 Delta ASDA B2...
Page 112: ...SHANGHAI WEIHONG ELECTRONIC TECHNOLOGY CO LTD 109 116 The button definitions are shown below...
Page 114: ...SHANGHAI WEIHONG ELECTRONIC TECHNOLOGY CO LTD 111 116 The button definitions are shown below...
Page 115: ...SHANGHAI WEIHONG ELECTRONIC TECHNOLOGY CO LTD 112 116...
Page 117: ...SHANGHAI WEIHONG ELECTRONIC TECHNOLOGY CO LTD 114 116...