12
f) DIRECTION OF ROTATION
If the DIx is Inactive, the Direction of Rotation is Forward, otherwise, the direction of rotation will be REVERSE.
DIx
Time
Time
Inactive
Forward
Reverse
Active
Output
frequency
Figure 12.10:
Example of the Direction of Rotation function
g) LOCAL / REMOTO
If DIx is inactive, the Local command is selected, reverse the Remote command is selected.
h) JOG
The JOG command is the combination of the Run/Stop command with a speed reference via parameter P122.
DIx -
Run/Stop
DIx -
General Enable
Time
Time
Time
Inactive
Inactive
Active
Active
Output
frequency
JOG frequency
(P122)
Acceleration
ramp
Deceleration
ramp
Time
Active
Inactive
DIx -
JOG
Figure 12.11:
Example of the JOG function