Chapter 9
Maintenance
32708885 Geset 100
Version: 16.07.13
Page 62 of 77
GB
Semi-annual servicing (after appr. 1000 hours of operation)
Requirements
¥
Labeler is without electrical power.
¥
No transportation of products.
Required equipment
¥
Vacuum cleaner
Instruction
Please arrange the semi-annual maintenance as follows
Step
Procedure
1
Replace all *²air filter elements of *²switch cabinet, *² protective cabi-
nets....
2
Clean the system cover’s outside and the *²protective cabinet’s inside
with a vacuum cleaner.
Do
not
use air pressure from the shop air supply as it is often not dry
(oil-/ water residues). If humidity gets in the electronics, it may lead to
damages!
3
Check moving or rotating machine parts for bearing play. Possible
repairs have to be arranged professionally.
Annual servicing (after appr. 2000 hours of operation)
Requirements
¥
Labeler is without electrical power.
¥
No transportation of products.
Required equipment
¥
Bearing grease Proline, Pro 672U (92100772, food compliant)
*Product recommendation. Can be obtained from the Bluhm Weber Group with the eight-character article number.
Instruction
Please arrange the yearly servicing as follows.
Step
Procedure
1
Examine …
¥
Base conveyor
¥
*²Top conveyor
¥
Conveying belts
… for correct belt tension. Possible repairs have to be arranged im-
mediately and professionally. (Instruction s. pages 67 and 69).
2
Clean at all *²linear strokes the guiding- and piston rods and grease
them slightly.
*²Only if system has the appropriate features.
Summary of Contents for Geset 100
Page 2: ...Blank page ...