Commissioning of Soda/Sparkling Water
1.
Ensure the CO
2
bottle is connected firmly and safely to the pressure regulator
and that the gas tube is fitted correctly.
2.
3.
Turn off the water supply at the source. The 3-way valve is shut when the lever
is perpendicular.
4.
Purge the soda water line of any air by dispensing sparkling water from the tap
for 30 seconds.
5.
Turn on the water supply at the inlet. The 3-way valve is open when the lever is
parallel to the 1/4-inch outlet line.
6.
Turn on the SODA power switch on the back of the unit and dispense sparkling
water from the tap for 15 seconds allowing any excess CO
2
to be dispensed.
7.
Allow 2-5 minutes for the CO
2
tank to fill completely.
8.
Note:
The Bar pressure on the CO
2
gauge may increase during this step. Venting
from the CO
2
gauge and/or the pressure relief valve within the unit is normal.
9.
Dispense sparkling water from the tap for 10-15 seconds and allow the tank to
refill for approximately 1 minute. Repeat this process 1-3 more times or until
water carbonation is evident.
Note:
The pressure on the CO
2
gauge should fluctuate between 3-4 Bar during
this process and during normal operation.
10.
Allow 1-2 hours for the water to chill and to reach full carbonation.
Note:
A small amount of water will be dispensed after using the sparkling
feature for 1-2 seconds. This is normal as the CO
2
Copyright Sodatap© 2023 Page 26 STM1 Manual V10
2
Slowly open the CO valve on the bottle and set the regulator
Slowly open the CO valve on the bottle and set the regulator pressure at
approximately 3 bar (please read "gas replacement" section on page 34 for
a detailed guide to this step).
is purged from the line.
Please conduct a soapy water leakage test as detailed on page 34, item 7.
Slowly turn on the red regulator valve.