WL500
Manual
Page 5 Revision 4‐10‐2019
WARNING!
DO NOT OPERATE IF DAMAGED.
Unplug and isolate water supply if abnormal conditions
exist. Contact Waterlogic or authorized dealer for repair, service, and installation to avoid hazards.
WARNING!
HOT WATER. Unit produces Hot Water in excess of 80
o
C (175
o
F).
Water above 52
o
C
(125
o
F) can cause severe burns or scalding. Keep unauthorized people and children away from the
unit to avoid accidental dispensing of hot water.
WARNING!
CONNECT TO POTABLE WATER SUPPLY.
This system is to be used for water only and is
not intended for use where water is microbiologically unsafe or with water of unknown quality
without adequate disinfection before or after the system.
WARNING!
TIP HAZARD.
Dispenser could tip or fall causing serious injury. Always install unit on a
firm, flat, and level surface and secure the
WL500 Water Treatment System
to the base cabinet with
the screw provided to lock the components together. Secure unit to cabinet, wall, or floor if needed.
Never place heavy items on top of unit and never climb, stand, or hang on unit or storage cabinet to
prevent injury and damage.
WARNING!
UNIT IS HEAVY. TWO PERSON LIFT REQUIRED.
Transport unit empty and always use
material handling equipment or two people with proper lifting technique to reduce injury risk.
WARNING!
STORE AND TRANSPORT UNIT EMPTY.
ALWAYS SANITIZE BEFORE USE.
The unit must be
completely drained
before storing to avoid stagnation and reduce microbiological
contamination (potential bacterial growth). Always sanitize before use to eliminate any potential
microbiological contaminates.
CAUTION!
INDOOR USE ONLY.
Intended for Household Use.
Never expose to direct sunlight, heat
sources, or ambient air temperature above 37°C (100°F) or below 2°C (35°F). Install indoors and keep
unit away from excessive humidity. Never expose to freezing temperatures. Ensure there is
adequate clearance around the unit to allow refrigeration system condenser to dissipate heat.
Warmer environments require more clearance around the unit. Minimum clearance around all
surfaces of the machine is 2‐inches. Installs where the ambient temperature exceeds 27°C (80°F),
require a minimum of 4‐inches clearance for proper heat dissipation and efficient operation.
CAUTION!
USE A WATER PRESSURE REGULATOR. Waterlogic
will not be responsible for injury or
damage caused by excessive water pressure. Input or feed pressure must be 40 psi to 60 psi. Be
aware of any potential pressure surges caused by building/municipal pumping stations.
CAUTION!
USE UV STABILIZED SUPPLY LINES.
Feed the unit with a potable ambient or cold water
supply only.
Feed water over 37°C (100°F) can damage the treatment components. Water block
devices and external leak detectors are strongly recommended. Locate the unit as close to the water
supply and the electrical connections as possible. Locate the unit as close to the water supply and
the electrical connections as possible. Immediately isolate or close water supply valve and contact
service representative if leak is noticed.
Contact Waterlogic for assistance or help finding an Authorized Service Representative.