RESETTING THE HOT TANK OVERLOAD OR HIGH LIMIT SAFETY
1.
Green Compressor/Heater Switch must be in the
O=OFF
position
2.
Unplug the Power Cord from rear of
WL500
Water Treatment System.
3.
Remove the Side Panel by removing the Front Hatch and Side Panels.
4.
Locate the Hot Tank
5.
Press the Reset Button
6.
Replace the Lower Front Panel.
7.
Plug in the Power Cord.
8.
Turn on the Green Compressor / Heater Switch
I=ON
position
The Hot and Cold Tanks must be filled with water BEFORE turning on the
Red Heater and Compressor Switch.
9.
Verify the cooler is fully operational before installing it at the customers’ site.