Page 38 Revision 4‐10‐2019
REPLACEMENT COMPONENTS (CONSUMABLES)
Component
WLCP PN
Frequency of Replacement
8W UV Lamp Assembly
10‐7020
Every 12 months, or as required
Factory PN CT‐2045
Sparkling Chamber Level
Sensor Probe Assembly
10‐7250
To be maintained and descaled at every filter change.
Replace if needed. Factory PN CT‐2023
Hot Tank (with controls) 1.6L
Factory Set Point 85°C (185°F)
10‐7082
Every three to 3‐5 years depending on usage.
Descaling hot tank may be required on a regular basis
depending on filtration.
Factory PN HT‐3021
CO
2
Pressure Regulator
with tamper proof adjuster,
preset to 35‐45 psi, single
output pressure gauge, inline
shut‐off valve, ¼ quick connect
fitting, safety relief, and CO2
CGA‐320 thread adapter.
AK‐0003‐L00
Needed to ensure input
water pressure is adequate
for machine performance.
CAUTION!
Use only Waterlogic Replacement parts that can be obtained from
Waterlogic
or an
Authorized Waterlogic Dealer
, failure to do so will void the Warranty.
See Installation and Service Manual for additional information.
Hot Tank Service
Hot Tanks (with controls) must be replaced at least every 3‐5 years depending on usage. Descaling hot
tank may be required on a regular basis depending upon filtration and local water conditions. See
Installation and Service Manual for further details.
Surface Cleaning
Clean on a regular basis with damp lint free cloth. Never use harsh chemicals (alcohol or acid based) or
abrasive agents on any part of the product to avoid damage. A mild cleaner such as Simple Green or
equivalent is recommended.
DISPOSAL
End of Life
At the
end of this product’s life
, ensure that it is disposed of in an environmentally friendly manner
which is fully compliant
with all Federal/State/Local Requirements and Guidelines
. Do not dispose of
this appliance with normal household or business waste.