6.1.3
Liquid bio fuels
The engine can be operated on liquid bio fuels according to the specifications in tables "6-4
Straight liquid bio fuel specification" or "6-5 Biodiesel specification based on EN 14214:2012
standard". Liquid bio fuels have typically lower heating value than fossil fuels, the capacity of
the fuel injection system must be checked for each installation.
If a liquid bio fuel is to be used as pilot fuel, only pilot fuel according to table "Biodiesel
specification based on EN 14214:2012 standard" is allowed.
Table "Straight liquid bio fuel specification" is valid for straight liquid bio fuels, like palm oil,
coconut oil, copra oil, rape seed oil, jathropha oil etc. but is not valid for other bio fuel qualities
like animal fats.
Renewable biodiesel can be mixed with fossil distillate fuel. Fossil fuel being used as a blending
component has to fulfill the requirement described earlier in this chapter.
Table 6-4
Straight liquid bio fuel specification
Test method ref.
Limit
Unit
Property
ISO 3104
100
cSt
Viscosity at 40°C, max.
1)
2.0
cSt
Viscosity, before injection pumps, min.
24
cSt
Viscosity, before injection pumps, max.
ISO 3675 or 12185
991
kg/m³
Density at 15°C, max.
FIA test
Ignition properties
2)
ISO 8574
0.05
% mass
Sulphur, max.
ISO 10307-1
0.05
% mass
Total sediment existent, max.
ISO 3733
0.20
% volume
Water before engine, max.
ISO 10370
0.50
% mass
Micro carbon residue, max.
ISO 6245 / LP1001
0.05
% mass
Ash, max.
ISO 10478
100
mg/kg
Phosphorus, max.
ISO 10478
15
mg/kg
Silicon, max.
ISO 10478
30
mg/kg
Alkali content (Na+K), max.
ISO 2719
60
°C
Flash point (PMCC), min.
ISO 3015
3)
°C
Cloud point, max.
IP 309
3)
°C
Cold filter plugging point, max.
ASTM D130
1b
Rating
Copper strip corrosion (3h at 50°C), max.
LP 2902
No signs of corrosion
Rating
Steel corrosion (24/72h at 20, 60 and 120°C), max.
ASTM D664
15.0
mg KOH/g
Acid number, max.
ASTM D664
0.0
mg KOH/g
Strong acid number, max.
ISO 3961
120
g iodine / 100
g
Iodine number, max.
LP 2401 ext. and LP
3402
Report
4)
% mass
Synthetic polymers
Remarks:
If injection viscosity of max. 24 cSt cannot be achieved with an unheated fuel, fuel oil system has to be equipped with a
heater.
1)
Ignition properties have to be equal to or better than requirements for fossil fuels, i.e. CN min. 35 for MDF and CCAI max.
870 for HFO.
2)
Cloud point and cold filter plugging point have to be at least 10°C below the fuel injection temperature.
3)
Biofuels originating from food industry can contain synthetic polymers, like e.g. styrene, propene and ethylene used in
packing material. Such compounds can cause filter clogging and shall thus not be present in biofuels.
4)
Wärtsilä 50DF Product Guide - a16 - 9 September 2016
6-5
6. Fuel System
Wärtsilä 50DF Product Guide
Summary of Contents for WARTSILA 50DF
Page 1: ...WÄRTSILÄ 50DF PRODUCT GUIDE ...
Page 14: ...This page intentionally left blank ...
Page 40: ...This page intentionally left blank ...
Page 58: ...This page intentionally left blank ...
Page 102: ...This page intentionally left blank ...
Page 120: ...This page intentionally left blank ...
Page 154: ...This page intentionally left blank ...
Page 164: ...This page intentionally left blank ...
Page 176: ...This page intentionally left blank ...
Page 214: ...This page intentionally left blank ...
Page 232: ...This page intentionally left blank ...
Page 234: ...This page intentionally left blank ...
Page 237: ......
Page 238: ......
Page 239: ......