WPE DIESEL GENERATORS
INTRODUCTION
2
INTRODUCTION
Thank you for purchasing our product.
This product is guaranteed against faulty manufacture
for a period of 24 months or 1000 running hours from the
date of purchase. Please keep your receipt as proof of
purchase. Full T&C’s can be found on the warranty page
in this manual or our website
www.championpowerequipment.co.uk
This guarantee will be voided if the product is found to
have been abused or modified/tampered with in any way,
or not used for the application/purpose for which it was
intended.
Faulty goods should not be returned to the
place of purchase.
The generator should be returned to
the supplier of the product. No product can be returned
without prior permission, returning generators costs
are solely the responsibility of the user/owner. This
guarantee does not affect your statutory rights.
When contacting WPE about parts and/or service,
you will need to supply the complete model and serial
numbers of your product. Transcribe the information
found on your product’s nameplate label to the table
below
WPE TECHNICAL SUPPORT TEAM
44(0)1942 715 407
MODEL NUMBER
SERIAL NUMBER
DATE OF PURCHASE
PURCHASE LOCATION
IMPORTANT
1. Children should be kept at a safe distance from the
generator and NEVER allowed to operate it.
2. Your new generator needs a break in period of
approx. 10-20 hours with NO more 75% maximum
load being applied. After first 20 hours the oil MUST
be changed, recommended oil type is 10W30 part
or full Synthetic. Alternative types of oil can be
found in the oil chart further in the manual under
maintenance.Don’t touch the engine or muffler while
generator is in operation. Please pay attention to
warning and caution stickers on the generator.
3. Electrical equipment (including cable and plug
connecting component) should be in good condition
before starting and inspected prior to use.
4. If replacing circuit breaker it must be equivalent or
better in specification of the one to be removed.
5. Due to high mechanical stress, only rubber sheathed
cables are recommended to be used.
6. When using extension cords or mobile distribution
cabinet, the wire with 1.5mm2 cross section should
not be longer than 50 metres; and for 2.5mm2 cross
section wire should not be longer than 100 metres in
length.
7. With manual starting, always use decompression
lever. (ONLY on Open Frame Type)
8. On standard working ambient conditions (minus
5 to 40 degree Centigrade), the generator can be
operated at normal running loads. If the working
condition of circumstance are not normal either
too high or too low, the generator should be run at
a lower output of no more than 75% maximum load.
When temperature, altitude and humidity is higher
than standard working condition, the generator
MUST reduce the output load to no more than 75%
maximum load.
9. Before any inspection or maintenance of the
generator, the engine must be stopped and allowed
to cool for a minimum 30 minutes. Check and
maintain the generator according to the period table
and schedule sheet in the manual.
10. Except the daily maintenance or cleaning, any
inspection or readjustment should be conducted
by authorized professional person and source the
requested original components by them from the
supplier. (Contact your local dealers).
11. Your newly overhauled machine must endure a
breaking-in period of at least 10 hours, the output
should not exceed 75% of the maximum load.