37
W&T
The serial combi-port
Subject to error and alteration
5�2
RS232 mode (factory default)
The pin configuration of the RS232 port is identical to that of
a PC, which allows you to use standard cables.
DIP switch setting RS232
Mode
SW1
SW2
SW3
SW4
SW5
SW6
SW7
SW8
RS232
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
1
The terminating DIL switches SW6 and SW7 must
never be in the ON position when using the module in
RS232 mode. This will result in a significant increase in the
current draw and may cause the RS232 driver to fail.
Pin assignment and function RS232, D9 male
Pin
Direction
Signal
Description
Default Function (*)
1
IN
DCD
Data Carrier
Detect
Ignored
2
IN
RxD
Receive Data
Data in
3
OUT
TxD
Transmit Data
Data out
4
OUT
DTR
Data Terminal
Ready
12V for existing TCP connection
to a client or server
5
---
GND
Signal Ground
---
6
IN
DSR
Data Set Ready
Ignored
7
OUT
RTS
Ready To Send
Handshake output
+12V = ready to receive data
- 12V = not ready to receive data
8
IN
CTS
Clear To Send
Data output only if +3...12V
9
IN
RI
Ring Indicator
Ignored
(*)
Applies only to the hardware handshake setting
Summary of Contents for Com-Server++
Page 8: ...W T...
Page 26: ...26 W T Assigning the IP address...
Page 27: ...27 W T Subject to error and alteration 3 Supply voltage Com Server Com Server3x Isolated...
Page 30: ...30 W T Supply voltage...
Page 34: ...34 W T Network interface...
Page 41: ...41 W T Subject to error and alteration 6 LED displays Power Status Error LED Network LEDs...
Page 88: ...88 W T Packetizing serial datagrams...
Page 94: ...94 W T Mode TCP server...
Page 108: ...108 W T Mode TCP client...
Page 122: ...122 W T UDP bus mode...
Page 130: ...130 W T The Windows COM port redirector...
Page 138: ...138 W T Box to Box mode...
Page 154: ...154 W T Mode FTP client...
Page 164: ...164 W T Mode Telnet Client...
Page 182: ...182 W T OPC data transfer...
Page 186: ...186 W T Mode InQueueCopy...