12
W&T
1�3
Factory defauls settings
The list contains an overview of the most important settings.
For many applications, such as the W&T COM Port Redirector,
no additional configurations need to be made besides assig-
ning the network base parameters. Detailed information on
the respective parameters can be found in later sections of
this manual.
Network settings
Hardware connection:
Auto negotiating
IP address:
0.0.0.0
Gateway address:
0.0.0.0
Subnet mask:
255.0.0.0
DHCP:
Active
1
To prevent unintended address assignments or
changes, we recommend deactivating the DHCP protocol
if it is not expressly used in the respective network environ-
ment.
Serial settings
Hardware connection:
RS232
Baud rate:
9600
Data bits:
8
Parity:
NO
Stop bits:
1
Handshake:
None
Fifo:
OFF
Configuration access
Per Telnet using TCP port 1111
Network applications / Operating mode
(suitable for use with W&T COM redirector)
TCP server ports, port no. A-C:
8000, 8100, 8200
Control port TCP, port no. A-C:
9094, 9194, 9294
Summary of Contents for Com-Server++
Page 8: ...W T...
Page 26: ...26 W T Assigning the IP address...
Page 27: ...27 W T Subject to error and alteration 3 Supply voltage Com Server Com Server3x Isolated...
Page 30: ...30 W T Supply voltage...
Page 34: ...34 W T Network interface...
Page 41: ...41 W T Subject to error and alteration 6 LED displays Power Status Error LED Network LEDs...
Page 88: ...88 W T Packetizing serial datagrams...
Page 94: ...94 W T Mode TCP server...
Page 108: ...108 W T Mode TCP client...
Page 122: ...122 W T UDP bus mode...
Page 130: ...130 W T The Windows COM port redirector...
Page 138: ...138 W T Box to Box mode...
Page 154: ...154 W T Mode FTP client...
Page 164: ...164 W T Mode Telnet Client...
Page 182: ...182 W T OPC data transfer...
Page 186: ...186 W T Mode InQueueCopy...