178
W&T
OPC data transfer
Local Port und Control Port
SETUP Port x
TCP/IP Mode
...
Port List
...
Local Port TCP/UDP
Control Port TCP
If a TCP port differing from the factory default set
8000
was
entered in the
OPC server
, the corresponding values must
also be configured in the menu branches of the Com-Server
shown above. The
Control Port
Number used by the
OPC ser-
ver
is always calculated from the formula
Data Port + 1094
.
Keep Alive Time
SETUP System
Setup TCP/IP
Keep Alive Time
...
The factory default setting for the keep-alive check is 30 se-
conds. I.e. if there is no data traffic the Com-Server checks
during the set time interval to see whether the connected
network application can be reached. If there is no reply, for
example due to a break in the network infrastructure, the
Com-Server resets the connection internally and thus enables
a new connection to be opened. Details can be found in sec-
tion
Menu SETUP System
r
Setup TCP/IP
.
Summary of Contents for Com-Server++
Page 8: ...W T...
Page 26: ...26 W T Assigning the IP address...
Page 27: ...27 W T Subject to error and alteration 3 Supply voltage Com Server Com Server3x Isolated...
Page 30: ...30 W T Supply voltage...
Page 34: ...34 W T Network interface...
Page 41: ...41 W T Subject to error and alteration 6 LED displays Power Status Error LED Network LEDs...
Page 88: ...88 W T Packetizing serial datagrams...
Page 94: ...94 W T Mode TCP server...
Page 108: ...108 W T Mode TCP client...
Page 122: ...122 W T UDP bus mode...
Page 130: ...130 W T The Windows COM port redirector...
Page 138: ...138 W T Box to Box mode...
Page 154: ...154 W T Mode FTP client...
Page 164: ...164 W T Mode Telnet Client...
Page 182: ...182 W T OPC data transfer...
Page 186: ...186 W T Mode InQueueCopy...