99
W&T
Mode TCP client
Subject to error and alteration
n
Connection Timeout
Default: 300
This value is a connection timeout that is only effective
together with an activated
Inactivity Timeout
. After the
Inactivity Timeout
expires, the Com-Server tries to send
any still existing, unsent user data for the duration of the
Connection Timeout. If it receives no reply from the TCP
server within this time, you may assume the connection is
„hanging“; the data are then rejected and the connection
reset. To prevent unintended loss of data, make this value
sufficiently large. Connection Timeout = 0 deactivates re-
setting of the connection after a timeout.
1 tick: 1 Second
Format: decimal