177
W&T
OPC data transfer
Subject to error and alteration
22�3
Configuration of the OPC server
The OPC Server is implemented as a background service, and
can be used without a user login. Configuration is file-based,
whereby the configuration files contain general options and
a device list. Any number of these files may be stored under
any desired names. This allows you for example to preserve
earlier work states or administer alternate configurations.
The configuration which the OPC Server actually uses is on the
other hand stored under a pre-defined name in the Windows
standard directory for common application data. It is automa-
tically read when the configuration program is started, and
as log as it it open the title line shows „Active configuration“
instead of the actual file name.
1
All changes made from within the configuration tool
do not become active until the menu item
File
r
Save
has been invoked as the active configuration.
22�3�1 Optional settings on the Com-Server
Starting from the factory default setting, only the three net-
work-specific parameters
IP Address
,
Subnet Mask
and
Gate-
way Address
need to be configured in order to operate the
Com-Server. It is not necessary to set the serial transmission
parameters such as baud rate, since these are automatically
made by the OPC Server.
Summary of Contents for Com-Server++
Page 8: ...W T...
Page 26: ...26 W T Assigning the IP address...
Page 27: ...27 W T Subject to error and alteration 3 Supply voltage Com Server Com Server3x Isolated...
Page 30: ...30 W T Supply voltage...
Page 34: ...34 W T Network interface...
Page 41: ...41 W T Subject to error and alteration 6 LED displays Power Status Error LED Network LEDs...
Page 88: ...88 W T Packetizing serial datagrams...
Page 94: ...94 W T Mode TCP server...
Page 108: ...108 W T Mode TCP client...
Page 122: ...122 W T UDP bus mode...
Page 130: ...130 W T The Windows COM port redirector...
Page 138: ...138 W T Box to Box mode...
Page 154: ...154 W T Mode FTP client...
Page 164: ...164 W T Mode Telnet Client...
Page 182: ...182 W T OPC data transfer...
Page 186: ...186 W T Mode InQueueCopy...