224
W&T
Appendix
Technical data and formfactor 58665
Supply voltage ���
Power-over-Ethernet
External supply...
... DC
... AC
37 - 57V DC from PSE
12 - 48V DC (+/- 10%)
18 - /- 10%)
Current draw
typ. 55mA @ 24VDC
PoE Class 1 (0,44 - 3,84W)
Permissible ambient temperatur ���
... storage
... operation
-40 ... +70°C
0 ... +60°C
Permissible relative humidity
0 ... 95% (not condensing)
Network
10/100BaseT, RJ45 for STP cables
Galvanic Isolation
Network: 1,5kV rms
Dimensions
approx. 105 x 75 x 22mm,
Weight
approx. 150g
Serial ports
1 x RS232/422/485 configurable,
DB9/Male
Baud rates
50 bis 230.400 kBit/s
Data formats
7, 8 daten bits, 1, 2 stop bits
NO, EVEN, ODD Parity
Flow control
Hardware handshake or
Xon/Xoff protocol
Front view 58661, 58665
Bottom side 58661, 58665
Serial Port
Power
Network
Status
17
75
23
108
Error
Measure in mm. +/-1mm
Summary of Contents for Com-Server++
Page 8: ...W T...
Page 26: ...26 W T Assigning the IP address...
Page 27: ...27 W T Subject to error and alteration 3 Supply voltage Com Server Com Server3x Isolated...
Page 30: ...30 W T Supply voltage...
Page 34: ...34 W T Network interface...
Page 41: ...41 W T Subject to error and alteration 6 LED displays Power Status Error LED Network LEDs...
Page 88: ...88 W T Packetizing serial datagrams...
Page 94: ...94 W T Mode TCP server...
Page 108: ...108 W T Mode TCP client...
Page 122: ...122 W T UDP bus mode...
Page 130: ...130 W T The Windows COM port redirector...
Page 138: ...138 W T Box to Box mode...
Page 154: ...154 W T Mode FTP client...
Page 164: ...164 W T Mode Telnet Client...
Page 182: ...182 W T OPC data transfer...
Page 186: ...186 W T Mode InQueueCopy...