1
05.09
ILV
TO.920.
T.
-
-
-
-
Electrical features - Elektrische Eigenschaften
06
OPERATING CONDITIONS
BETRIEBSBEDINGUNGEN
CONDITIONS DE FONCTIONNEMENT
CONDIZIONI DI FUNZIONAMENTO
Type
Relay output
PNP Output
Power supply voltage
19…230V 50/60Hz +10% / 19…50V DC +10%
18…50V +10%
Maximum oscillation
7Vss DC
7Vss
Power absorbed
Max. 18VA/ 2W
Max. 0.6W (ILVA/ILVB)
Max. 1.5W (ILVC)
Cable gland
M20x1.5
Signal output
AC Max 250V,8A non inductive
DC Max. 30V, 5A non inductive (ILVA-ILVB)
Permanent charge max. 0.4° protected against short-circuit
and overload. Voltage for protection against polarity
inversion max. 55V
AC max. 253V, 4A, 500VA Phi =1
DC Max. 253V, 4A 60W (ILVC)
Signal delay
Uncovered probe covered for approx. 1sec.
Covered probe uncovered for approx 1..2 sec.
Safety operation (FSL, FSH)
Can be switched for minimum/maximum safety
Sensitivity
Adjustable at two levels
Measuring frequency
Approx. 200 Hz (ILVA-ILVB)
Approx. 125 Hz (ILVC)
Insulation
Power supply and output signal 2225 VRMS
-
Protection Class
I
III
Typ
Relaisausgang
PNP Ausgang
Speisespannung
19…230V 50/60Hz +10% / 19…50V DC +10%
18…50V +10%
Max. Oszillation
7Vss DC
7Vss
Anschlusswert
Max. 18VA/ 2W
Max. 0.6W (ILVA/ILVB)
Max. 1.5W (ILVC)
Kabelverschraubung:
M20x1.5
Ausgangssignal
AC Max 250V,8A nicht induktiv
DC Max. 30V, 5A nicht induktiv (ILVA-ILVB)
MAX. Dauerlast 0.4° bei Kurzschluss- und
Überlastungstest. Schutzspannung gegen Umkehr der
Polarität max. 55V
AC max. 253V, 4A, 500VA Phi =1
DC Max. 253V, 4A 60W (ILVC)
Signalverzögerung
Sonde frei bedeckti um 1sec.
Sonde bedeckt frei um 1..2 sec.
Sicherheitsbetrieb (FSL, FSH)
umschaltbar auf kleinstes/größtes Sicherheitsniveau
Empfindlichkeit
Auf zwei Stufen einstellbar
Messfrequenz
Um 200 Hz (ILVA-ILVB)
Um 125 Hz (ILVC)
Isolation
Stromversorgung und Ausgangssignal 2225 VRMS
-
Schutzart
I
III