80
wallaceperimetersecurity.com
Phone: 866.300.1110
INSTALLER MENU FUNCTIONS
Table 5. SmartDC Controller - Installer Menu Functions
Table 5. SmartDC Controller - Installer Menu Functions
Ref.
No�
Installer Menu
Setting Options
(
Bold
= Factory Settings)
Menu Tasks and Explanations
Associated
DC Controller
Connections
Display
25
PC 1 NC CONTACT
PHOTO EYE OUTPUT
0 = Normally Open PE
output
1 = Normally Closed
(supervised)
This menu item only appears when UC is
set to 4.
The default setting is photo eyes
with Normally Close outputs. The optional
setting 0 requires a Normally Open (NO)
output. When set for NC, the connection
is monitored and any open or short circuit
fault will generate a FAULT 2 alert which
requires a STOP or RESET button press to re-
enable gate operation.
Photo eye
connections:
Sensor
Common
Sensor Input
+24V
26
S1 0
SENSOR #1 TYPE
0 = disabled
1 = (NOT USED)
2 = (EYE CLOSE)
3 = (EDGE CLOSE
4 = (EYE OPEN)
5 = (EDGE OPEN)
6 = (EDGE BOTH)
7 = (EYE BOTH)
UL 325 - 2018 sensor input setting for
external entrapment protection sensor
monitoring. All three sensor types must be
configured to a non-zero number before
the gate operator will move the gate. Edge
Both is only available in Swing Gate operator
types. Eye Both is only available in Slide Gate
operator types.
--
27
S2 0
SENSOR #2 TYPE
Same as Sensor 1.
Same as Sensor 1.
--
28
S3 0
SENSOR #3 TYPE
Same as Sensor 1.
Same as Sensor 1.
--
29
DT 0 FREE EXIT
DISABLE FUNCTION
0 = Disable Free Exit
1 = Disable Close Timer
Configures the BLOCK EXIT input to disable
either the Free Exit Detector function or,
alternately, the Close Timer function. The
default setting disables the free exit detector.
Note:
The free exit is disabled when the
gate is at its closed limit. If the closed limit is
not tripped, the free exit continues to work
normally.
BLOCK EXIT
COM
Summary of Contents for FOLDSMART
Page 36: ...36 wallaceperimetersecurity com Phone 866 300 1110 FOLDSMART GATE INSTALLATION ...
Page 38: ...38 wallaceperimetersecurity com Phone 866 300 1110 FOLDSMART GATE INSTALLATION ...
Page 146: ......
Page 147: ...FoldSmart XT Drawings Generic Site Layout and Options ...
Page 148: ......
Page 149: ......
Page 150: ......
Page 151: ......
Page 152: ......
Page 153: ......
Page 154: ......
Page 155: ......
Page 156: ......
Page 157: ......
Page 158: ......
Page 160: ......