98
wallaceperimetersecurity.com
Phone: 866.300.1110
USER RELAYS - PROGRAMMING PROCEDURE
Table 8. User-Programmable User Relays - Function Options
No�
Name
Description
7
Gate forced open output
Activated if the gate is forced off the closed limit switch and operator is not
able to restore the gate to full closed within four seconds. The buzzer resets
itself in 30 seconds but relay stays active until gate receives a run command
.
8
Gate open too long output Activates when the gate is open longer than a user-selected period of time.
Adjustable from a 0 second to 135 second delay in 15-second increments.
Note: TL - OPEN TIME ALERT adjustments can be made in the Installer Menu.
9
Safety Mode Alert output Activated when system is in the Safety Mode or the Entrapment Mode.
Safety Mode occurs upon an impact with an obstruction. Entrapment
Mode means the gate is stopped and occurs if the internal inherent
entrapment sensor triggers while the system is in the Safety Mode.
10
Entrapment Mode Alert
output
Activated only when system is in the Entrapment Mode.
11
Unauthorized Vehicle
Entry output
Activated when a second vehicle enters from the outside without
a valid input from an access control device. The OOLD and IOLD
loops must be capable of being triggered at the same time for this
relay to ever activate. This output releases when an access control
input signals open or the gate reaches the close limit position.
12
Outside Obstruction
Vehicle Detector output
This output is active whenever the Outside Obstruction Loop Detector
is tripped. Interlocks an entry device to prevent pedestrian use.
13
Loitering Alert
Indicates a vehicle or loitering on the Outside Obstruction Loop with the
gate closed. Adjustable from a 0 second to 135 second delay in 15-second
time intervals.
Note: LT - LOITERING ALERT adjustments can be made in the Installer
Menu.
14
Gate nearing full travel
output
Activated when the gate is approaching full open or full closed, or in a
reverse travel mode.
15
Gate Failure output
Activated to report occurrence of a problem. Indicates the system is in an
Error Mode, Fault Mode or Entrapment Mode. If active, the gate is disabled.
16
Motor Running output
Active when the motor is running and the gate is in motion.
17
AC Power Failure output
This relay is normally energized and drops with loss of AC power.
18
DC Power Failure output
Activated when the battery power is very low, but the output ceases when
the battery is dead (18 volts). The relay is triggered when the battery is
less than 21 volts
.
19
Flasher Relay
Controls flashing lights that pulse once per second. The relay is
constantly pulsing except when the open limit switch is triggered.
Recommended to use User Relay 2 since it is an electronic switch.
20
Free Exit Loop Vehicle
Detector output
Active whenever the Exit Loop is tripped.
21
Inside Obstruction Vehicle
Detector output
Activated when the Inside Obstruction Vehicle Detector is tripped.
22
Center Loop Detector
output
Activated when the Center (Shadow) loop detector is tripped.
Summary of Contents for FOLDSMART
Page 36: ...36 wallaceperimetersecurity com Phone 866 300 1110 FOLDSMART GATE INSTALLATION ...
Page 38: ...38 wallaceperimetersecurity com Phone 866 300 1110 FOLDSMART GATE INSTALLATION ...
Page 146: ......
Page 147: ...FoldSmart XT Drawings Generic Site Layout and Options ...
Page 148: ......
Page 149: ......
Page 150: ......
Page 151: ......
Page 152: ......
Page 153: ......
Page 154: ......
Page 155: ......
Page 156: ......
Page 157: ......
Page 158: ......
Page 160: ......