32
GM 5000EA
B_04382
OPERATING MANUAL
EDITION 04/2016
ORDER NUMBER DOC2344499
Spraying direction
Rotate upward
Stop
to front
Smaller cross-section
Rotate downward
Stop
to back
Larger cross-section
5.6.2
PRESSURE SETTINGS FOR FLAT JET NOZZLES
5.6.3
ADJUSTING SCREW
By turning the lateral adjusting screw
of the gun, the outlet cross-section can be
adjusted on the product valve. This cross-section is minimized by turning the screw
upwards. With the same pressure settings, this results in a reduction of the fl ow rate and
fi ner atomization.
Note:
The spray pattern is reduced with this setting.
There are 8 fl at jet nozzle sizes from 0.6 up to 2.0 available. There are 2 air cap types
(s = small, w = wide) with 3 diff erent nozzle sizes each. Each air cap can be used in
combination with 2 to 3 nozzles sizes. Only matching nozzle components may be used.
Pressure settings
Air cap 0.6-0.8
Air cap 1.0-1.4
Air cap 1.6-2.0
Product pressure
0.5 bar to 1.0 bar
1.0 bar to 2.0 bar
1.0 bar to 3.0 bar
Atomizing air pressure
1.0 bar to 3.0 bar
1.5 bar to 4.0 bar
1.5 bar to 5.0 bar
The table contains default values. Depending on the product, conditions and the desired
result diff erent values are possible or necessary.
Air cap type
suitable nozzle sizes
0.4–0.8S / 0.4–0.8W
0.6 / 0.8
1.0–1.4S / 1.0–1.4W
1.0 / 1.2 /1.4
1.6–2.0S / 1.6–2.0W
1.6 / 1.8 /2.0