56
GM 5000EA
OPERATING MANUAL
EDITION 04/2016
ORDER NUMBER DOC2344499
Exploding gas / air mixture!
Danger to life from fl ying parts and burns.
Never spray into a closed tank.
Ground the tank.
DANGER
Clean nozzle
1. Switch off control unit.
2. Relieve pressure. Chapter 7.3.4
3. Close air pressure regulator.
4. Dismount nozzle and clean separately. Chapter 7.3.6
Flush spraying system and spray gun
5. Connect spraying system to fl ushing agent supply in accordance with operating
manual for the product pressure generator.
6. Point the spray gun toward the collecting tray and actuate the trigger. Flush the gun
thoroughly as soon as clean fl ushing agent emerges.
7. Remove fl ushing agent supply.
Blowing out the air passages of the spray gun
8. Close pump pressure regulator. Switch on compressed air supply and open air
pressure regulator.
9. Actuate the trigger of the spray gun and thoroughly blow out the air passages.
10. Switch off the compressed air supply.
Clean the outside of the spray gun
11. Clean the spray gun body and other components of the spraying system with a
cleaning agent recommended by the lacquer manufacturer and dry with a cloth or
blow gun.
Cleaning the nozzle parts
See Chapter 7.3.6