64
GM 5000EA
B_03248
SW19
SW19
4
5
6
B_04369
n
o
n
o
p
9
8
B_04370
SW11
OPERATING MANUAL
EDITION 04/2016
ORDER NUMBER DOC2344499
Carefully release the
cascade without pliers.
O-ring (8)
: 1. Use
screwdriver no. 1 to press
under the O-ring.
2. Lever up the O-ring and
remove it.
Air distribution (9)
: 1. Locate the start of the thread for recessed internal
threading.
2. Lever under the air distribution ring directly in front of the start of the
thread using screwdriver no. 1.
3. As soon as the ring disengages, carefully undo it on all sides.
Valve needle assembly tool
Order No. 2309368
Valve needle Air
Loosen valve tip by hand using the valve needle assembly tool (Order No. 2309368).
Valve housing
: Use socket or ring
spanner (not a wrench).