22
GM 5000EA
R1
R3
R2
B_03182
2
4
3
OPERATING MANUAL
EDITION 04/2016
ORDER NUMBER DOC2344499
5.2
MODE OF OPERATION
Display (2)
= Recipe values changed temporarily:
If the operating key (4) is pressed for 2 seconds, the saved recipe
values for the previously selected recipes numbers will be
reloaded from the memory.
When the spray gun is connected to the control unit and the
control unit is switched on, the pre-defi ned recipe (R1, R2 or
R3) is shown on the gun display (2) as follows.
Recipe 1
Recipe 2
Recipe 3
Recipe change R1 R2 R3 R1.
Press the operating button (4) and hold the button pressed for
at least 2 seconds to go forward 1 recipe.
During spraying mode (trigger lever pressed), the status is shown in the display (2) by LEDs.
LED display
Description
LEDs 1 - 3 light up green
The spray gun is working in an optimal
high-voltage spray current range.
One or both right-hand LEDs illuminate
in orange.
Spray current too high.
Possible causes:
(Warning display: You can continue
working without any limitations.)
- Spray gun too close to the work piece
- Contamination of the spray gun
- Paint conductivity too high