58
GM 5000EA
OPERATING MANUAL
EDITION 04/2016
ORDER NUMBER DOC2344499
DANGER
Incorrect maintenance/repair!
Danger to life and equipment damage.
Only a WAGNER service center or a suitably trained person may
carry out repairs and replace parts.
Only repair and replace parts that are listed in the "Spare parts"
chapter and that are assigned to the unit.
Before all work on the device and in the event of work
interruptions:
- Switch off the energy supply and the compressed air supply.
- Relieve the pressure from the spray gun and device.
- Secure the spray gun against actuation.
Observe the operating and service manual for all work.
For the safe operation of electrostatic manual coating systems for fl ammable liquid coating products,
intervals for periodical inspections are defi ned as follows:
Inspection point
Inspection interval
Remarks
Gun cleaning, gun fl ushing
daily
Chapter 4.2.4, Chapter 8.1
Hoses, tubes, couplings
daily
Chapter 8.2.4
Grounding
weekly
Chapter 4.2.2, Chapter 6.5.5
Inspection for damage
weekly
Chapter 8.1.3, 8.2, 10
Locking of the technical ventilation with the
electrostatic manual spraying unit
annually
Chapter 6.5.2
The above recommended intervals are maximum values and may be modifi ed by the operator depending on
the local and operational conditions and the contamination.
Damaged devices must be decommissioned and repaired immediately.
8.2.3
SAFETY CHECKS