52
GM 5000EA
B_03518
OPERATING MANUAL
EDITION 04/2016
ORDER NUMBER DOC2344499
7.3.7
CHANGING THE VALVE HOUSING
Changing the valve housing!
Damage to the device.
Activate the spray gun trigger when changing the valve housing.
NOTICE
To prevent damage to the gun
(valve seat rubs on the valve
needle, valve needle may loosen),
activate the spray gun trigger
when changing the valve housing.
Use a socket or ring spanner (not
a wrench) to tighten the valve
housing.
7.3.6
CLEANING OF THE NOZZLE PARTS
The nozzle parts (2, 3, 4, 5 and 6) may only be immersed into a cleaning solvent
recommended by the lacquer manufacturer and must be removed again immediately.
They may only remain in a cleaning solvent for a short time.
Clean these parts with a brush and dry them with a cloth or a blow gun.
Valve housing and valve tip are available in various materials:
Valve housing
Valve tip
Material of the valve seat
Product
Standard version
Steel
PEEK
Special accessories
PEEK
Steel
When wear-related problems occur, the valve housing and/or valve tip can be exchanged.
Order No., see Chapter 13.