INSTRUCTIONS AND PARTS LIST, LMS-E6-45 9/5/2018
WARNING:
Spray materials may be harmful if inhaled or allowed
to come into contact with skin or eyes. Consult the product label
and Material Safety Data Sheet supplied for the spray material.
Follow all safety precautions.
CAUTION:
Well Ventilated
Area Required to remove fumes, dust or overspray. Check
compatibility of materials used with Polyethylene container
and PVC Fluid Hose. Secure airhose and fluid hose
wrench tight for safety and to prevent leaks.
M a x i m u m A i r P r e s s u r e 8 0 P . S . I .
M a x i m u m F l u i d P r e s s u r e 4 5 P . S . I .
LMS-E6-45
SPRAY GUN
OPERATING INSTRUCTIONS AND REPLACEMENT PARTS
INTRODUCTION:
This Spray Gun is best suited for thin to medium viscosity materials.
Spray Gun needs to be fed from a Pressure Feed Tank, Fluid Pump, or Pressure Feed Cup.
OPERATION:
Strain Fluid before spraying.
AIR AND FLUID CONNECTIONS:
Attach Airhose to 1/4” N.P.T.
1. Air Connection: To remove any accumulated foreign matter blow out all hoses before using.
a. Air supply to Spray Gun must be turned off before attaching fitting to the Air Inlet.
b. Attach Air Hose to the Air Outlet on the Air Regulator and Air Inlet on the bottom of the handle on
the Spray Gun.
Attach Fluid Hose to 3/8” N.P.S.( Make sure all fittings are tight).
2. Fluid Hose: Run Fluid Hose from Spray Gun to Pressure Pot.
a. Attach Hose to the fluid inlet of the Fluid Body.
Air and Fluid Pressure Setup:
Start fluid pressure at 25 PSI and air pressure at 30 PSI. Air should be 5-10 PSI over fluid pressure.
From there you can increase fluid and air pressures to assist in spraying thicker fluids.
Keep the air pressure 5-10 PSI higher as you increase the fluid to prevent backflow into your pressure tank.
(Maximum fluid pressure 40 PSI or lower depending on pressure tank limits)
Air & Fluid Pressures may vary with Extension Length or Viscosity.
Adjustment Knob at the rear of the Gun controls your Needle Stroke. (Needle shuts material off at the tip).
Insert tip of Extention Wand into item being coated, pull trigger and pull back the Gun with a smooth stroke.
This Manual Spray Gun requires clean dry air. Paasche Regulator & Condenser Units are recommended for
attaching to air supply line to remove water, oil, rust or scale and help insure a quality finish of coating.
Printed in the U.S.A.