Maintenance
Periodic Maintenance Schedule 7.1
65
[en-US] | 09/2022 | 5100061327 | RTLx-SC3 | Operator’s Manual
7
Maintenance
7.1
Periodic Maintenance Schedule
Maintenance cycle
Personnel
For further information
Daily
Operating personnel
Checking the Hydraulic Oil Level
Checking for Loose or Missing Fasteners
Cleaning SmartControl™ Transmitter
100 hours
Operating personnel
Lubricating the Articulated Joint and Steering
Cylinders
Draining the Fuel and Water Separator
300 hours
Operating personnel
1000 hours
Service personnel
Changing the Hydraulic Oil and Filter
As needed
Operating personnel
Maintenance personnel
Machine Disposal and Decommissioning
7.2
Checking the Hydraulic Oil Level
NOTICE
Low levels of hydraulic oil may cause damage to hydraulic components.
►
If hydraulic oil continually needs to be added, inspect the hoses and
connections for possible leaks. Repair any leaks immediately.
►
Do not attempt to remove the vent cover from the hydraulic reservoir.
When
Daily
Requirements
Location
A hydraulic oil level sight glass
(1)
is located on the side of the hydraulic fluid
reservoir inside the rear section of the machine.