Operation
Light Ring Color Codes 6.9
39
[en-US] | 09/2022 | 5100061327 | RTLx-SC3 | Operator’s Manual
Ref
Color and
appearance
Status
Transmitter function
Cause
Remedy
1
Green (blink-
ing rapidly) or
Red (steady)
Joystick or
function key
error
Transmitter unable to
control the machine.
Operating error within a
function key, or one or
both joysticks.
Contact Product Sup-
port.
2
6.9
Light Ring Color Codes
Color—Code
Mode
Reason / Remedy
Amber—solid
Non communica-
tion
Machine’s key in ON position, but:
• Transmitter is not turned on.
• Transmitter battery is dead.
• Transmitter not pointed at machine.
• Transmitter too far from machine.
• Transmitter and decoder are on different channels.
• Communication fault (For further information, see
Communication
Faults
.)
Amber—slow flash Normal operation Machine is receiving proper signal from transmitter and is operational.
Amber—fast flash
Operator safety
Machine is receiving signal but operator is too close to machine.
• Move farther than two meters (6 feet) from machine until amber lights
flash slowly.
Red—solid
Machine shut
down
Critical error has occurred such as: tip over, low oil pressure, or high
coolant temperature.
• For tip over: Turn key OFF, upright machine. For further information,
see
Resetting the ECM Diagnostic Data and the Tip-over Light
.
• For low oil pressure: Turn key OFF. Check oil. Restart as normal.
• For high coolant temperature: Turn key OFF. Allow machine to cool.
Add coolant.
Red—slow flash
Automatic glow
plug
Glow plugs are preheating engine. No functions allowed until preheat cy-
cle is complete.
Red—fast flash
Over voltage
Machine is receiving more than 18 Volts due to non-12V system used for
jump starting.
• Replace machine’s 12V battery.
• Do not jump-start the machine.
6.10
Infrared System and Control Channels
Overview
The infrared (IR) system consists of three main components: the SmartCon-
trol
TM
SC-3 transmitter
(1)
, the receiving eyes
(2)
, and the decoder mod-
ule
(3)
.
The receiving eyes are positioned on the top of the machine enclosed within
protective lenses. They receive, filter, and amplify the infrared transmission.
They include:
6
Summary of Contents for RTLx-SC3
Page 6: ...This page is intentionally left blank...
Page 89: ...Index 89 en US 09 2022 5100061327 RTLx SC3 Operator s Manual...
Page 92: ...Cette page est laiss intentionnellement vierge...
Page 183: ...Index 183 fr 09 2022 5100061327 RTLx SC3 Notice d utilisation...
Page 184: ......
Page 185: ......