wc_tx003863gb_FM10.fm
61
RT / RTx
Operation
4.17
Operating Characteristics
■
In some instances, objects passing between the machine and transmitter (such
as support beams) will block the signal. When this occurs, the machine will stop
moving. If the signal is not re-established within 30 seconds, the engine will shut
down.
■
In an enclosed area (such as a shop floor or warehouse) or an area surrounded
by large structures, the infra-red signal may reflect off surrounding surfaces,
causing it to be picked up by the machine even when the transmitter is pointed
away from the machine. This condition is more pronounced at shorter distances
when the signal strength is strong.
■
As the distance between the transmitter and machine increases, the intensity of
the signal diminishes.
4.18
Communication Faults
Description
The decoder has built-in diagnostics that continuously check for a faulty signal
transmitted from the receiving eyes to the decoder. If a faulty signal is detected, the
decoder stops machine movement and the light rings illuminate solid amber.
Fault
correction
Communication faults may occur when a receiving eye is damaged. The faults vary
in frequency and duration. When a normal signal is restored, the light rings slowly
flash amber and machine movement is restored.
If communication faults occur regularly, check the condition of the receiving eyes.
Replace damaged components as needed.
WARNING
Personal injury or equipment damage hazards. The roller's sensing system will not
stop the roller from moving when the transmitter is in the storage compartment or
on the side of the roller.
►
When operating from the side of the machine, always maintain a distance of at
least 2m (6.6 ft.) from the machine.
►
Never operate the machine with the transmitter in the storage compartment.
Summary of Contents for RT82-SC3
Page 4: ...CALIFORNIA Proposition 65 Warning wc_tx004643en fm 4 Notes...
Page 8: ...Foreword RT RTx 8 wc_tx003861gb_FM10 fm...
Page 10: ......
Page 12: ......
Page 25: ...wc_si000902gb_FM10 fm 25 RT RTx Safety Information Notes...
Page 40: ...wc_tx003862gb_FM10 fm 40 Lifting and Transporting RT RTx Notes...
Page 56: ...wc_tx003863gb_FM10 fm 56 Operation RT RTx wc_gr012189 a b c d e f...
Page 122: ...wc_td000626gb_FM10 fm 122 Technical Data RT RTx Notes...
Page 151: ...RT RTx Schematics wc_tx003865gb_FM10 fm 151 14 Schematics Notes...
Page 178: ......
Page 180: ......