wc_tx003818gb_FM10.fm
77
RT / RTx
Engine Control Module (ECM) Diagnostics
Continued from the previous page.
If the wire
(c)
to the starter solenoid is disconnected or the starter solenoid is faulty,
the following results occur.
■
The control panel indicators will flash immediately after the starter pushbutton is
pressed.
■
The red LEDs of the light ring will illuminate solid red.
■
The engine will not crank.
Reconnect the wire or replace the starter solenoid to enable the machine to start.
wc_gr012439
c