When all LEDs flash rapidly, there is a hazard of over compaction or the machine is
on a substrate that is too hard.
Note:
Non-compactible material or flaws in the substrate are detectable by the
system if they are more than 1 meter in length. With sudden changes from high to
low compacted soil (or vice versa), there is a slow rise or fall in the LEDs.
NOTICE:
The Compatec compaction system automatically switches off as soon as
the starting key is set to the OFF position. However, if the starting key remains in
the ON position when the engine is not running, the LED display will draw current
from the battery.
Testing
Test the Compatec compaction system upon machine start up.
1. Rotate the starting key clockwise to the ON (I) position.
2. Observe the LED display. During the first few seconds after turning the starting
key to the ON (I) position, the eight LEDs illuminate from left to right.
If
Then
All LEDs illuminate,
The system is fault free and the LEDs switch off in
succession. Then, all eight LEDs flash briefly with
reduced brightness.
All LEDs illuminate and remain
illuminated after initialization,
The sensor is not functioning properly.
Summary of Contents for RT82-SC3
Page 4: ...CALIFORNIA Proposition 65 Warning wc_tx004643en fm 4 Notes...
Page 8: ...Foreword RT RTx 8 wc_tx003861gb_FM10 fm...
Page 10: ......
Page 12: ......
Page 25: ...wc_si000902gb_FM10 fm 25 RT RTx Safety Information Notes...
Page 40: ...wc_tx003862gb_FM10 fm 40 Lifting and Transporting RT RTx Notes...
Page 56: ...wc_tx003863gb_FM10 fm 56 Operation RT RTx wc_gr012189 a b c d e f...
Page 122: ...wc_td000626gb_FM10 fm 122 Technical Data RT RTx Notes...
Page 151: ...RT RTx Schematics wc_tx003865gb_FM10 fm 151 14 Schematics Notes...
Page 178: ......
Page 180: ......