wc_tx003819gb_FM10.fm
94
General Maintenance
RT / RTx
7.3
Checking the Hydraulic Oil Level
A hydraulic oil level sight gauge
(a)
is located on the hydraulic reservoir inside the
rear section of the machine.
While the machine is turned off, check that the hydraulic oil level is visible at the
middle level or higher in the sightglass. If it is not, add oil as required through the
filter housing on top of hydraulic reservoir. Use only clean hydraulic oil.
Thoroughly clean the top of the filter cover
(b)
before removing it from the reservoir.
Care should be taken to prevent small dirt particles from entering the system.
NOTICE
■
If hydraulic oil continually needs to be added, inspect hoses and connections for
possible leaks. Repair hydraulic leaks immediately to prevent damage to
hydraulic components.
■
Do not attempt to remove the vent cover from the hydraulic reservoir.
a
b
wc_gr012190