Operation
G 50/G 70/G 85
wc_tx000483gb.fm
26
3.2
Generator Monitoring
Generator information is displayed on the top line of the LCD panel and
is scrolled continuously while the generator is operating, to show the
voltage, amperage and frequency of each phase.
Note:
To prevent the display from scrolling, press the ENG HRS switch
down.
Volts “V”
- Displays the AC output voltage being produced by the
generator.
Phase “Ø”
- Indicates which phase is currently being displayed.
Amps “A”
- Displays the AC output amperage produced by the
generator. If the generator is operating at no-load, output amperage
will display a 0.
Hertz “Hz”
- Displays output frequency.
Sample display with engine running.
Sample display in “Auto” mode.
208 1 24 60
78 85% 175 14.3
UNIT IN AUTO
Ø 100% 85 13.2
Summary of Contents for G70
Page 2: ......
Page 14: ...Safety Information G 50 G 70 G 85 wc_si000158gb fm 14 2 6 Label Location...
Page 15: ...G 50 G 70 G 85 Safety Information wc_si000158gb fm 15...
Page 24: ...Operation G 50 G 70 G 85 wc_tx000483gb fm 24 3 Operation 3 1 Control Panels...
Page 46: ...Operation G 50 G 70 G 85 wc_tx000483gb fm 46 w c _ g r 0 0 0 5 1 0 a d c b...
Page 57: ...G 50 G 70 G 85 Maintenance wc_tx000484gb fm 57...
Page 59: ...G 50 G 70 G 85 Maintenance wc_tx000484gb fm 59...
Page 65: ...G 50 G 70 G 85 Maintenance wc_tx000484gb fm 65 G 50 G 70 Engine Wiring...
Page 67: ...G 50 G 70 G 85 Maintenance wc_tx000484gb fm 67 G 50 G 70 Engine Wiring...
Page 69: ...G 50 G 70 G 85 Maintenance wc_tx000484gb fm 69 G 50 G 70 Engine Wiring...
Page 73: ...G 50 G 70 G 85 Maintenance wc_tx000484gb fm 73...
Page 81: ...Mobile Generators Factory Installed Options wc_tx000380gb fm 81 Notes...
Page 90: ...Technical Data G50 G 70 G 85 90 6 4 Dimensions mm inches...
Page 91: ......