5.4
LCD Strip Heater
See Graphic: wc_gr001724, wc_gr001725
The LCD strip heater option includes a thermostat module
(a)
and a
clear heater strip that is bonded to the LCD
(b)
of the ECM. The
purpose of the strip heater is to prevent the LCD from being damaged
by extremely cold temperatures. The resistance of the coiled element
of the heater is sensed by the thermostat. The resistance of the
element changes with temperature. At approximately -30°C, the
resistance value triggers the thermostat to send power to the element.
The LED
(c)
of the thermostat module flashes during operation.
It is important to note that the LCD strip heater is always on and thus
draws power (a very small amount) from the battery even when the unit
is not running. If the battery should fail, the heater will also fail. Be sure
to keep the battery charged when the generator is not in use.
Summary of Contents for G70
Page 2: ......
Page 14: ...Safety Information G 50 G 70 G 85 wc_si000158gb fm 14 2 6 Label Location...
Page 15: ...G 50 G 70 G 85 Safety Information wc_si000158gb fm 15...
Page 24: ...Operation G 50 G 70 G 85 wc_tx000483gb fm 24 3 Operation 3 1 Control Panels...
Page 46: ...Operation G 50 G 70 G 85 wc_tx000483gb fm 46 w c _ g r 0 0 0 5 1 0 a d c b...
Page 57: ...G 50 G 70 G 85 Maintenance wc_tx000484gb fm 57...
Page 59: ...G 50 G 70 G 85 Maintenance wc_tx000484gb fm 59...
Page 65: ...G 50 G 70 G 85 Maintenance wc_tx000484gb fm 65 G 50 G 70 Engine Wiring...
Page 67: ...G 50 G 70 G 85 Maintenance wc_tx000484gb fm 67 G 50 G 70 Engine Wiring...
Page 69: ...G 50 G 70 G 85 Maintenance wc_tx000484gb fm 69 G 50 G 70 Engine Wiring...
Page 73: ...G 50 G 70 G 85 Maintenance wc_tx000484gb fm 73...
Page 81: ...Mobile Generators Factory Installed Options wc_tx000380gb fm 81 Notes...
Page 90: ...Technical Data G50 G 70 G 85 90 6 4 Dimensions mm inches...
Page 91: ......