61
7. Thread the 9-Tube Assembly coupler nut
onto the Lead’s casing and tighten to
secure.
NOTE:
THE 44-SYSTEMS WITH THE SPLIT
LEAD WILL CONNECT WITH THE TWO 9-
TUBE ASSEMBLIES OUTSIDE THE CABINET.
8. Gently lay the pump harness cable out and
away from the cabinet. Remove the open-
close bushing from the plate and wrap the
bushing around the pump harness cable
near the lower plate’s slotted hole. Snap
the grommet with the cable back into the
slotted hole in the plate.
Installing the Electronics Box and Power
Connections
The electronics box houses the electronics
board and most of the power connections for
the Deluxe unit. For shipping safety purposes,
the electronics box ships unconnected to the
unit. Follow these instructions to install the
electronics box to the back of the Deluxe
cabinet, connect the remaining power cables,
and power up the system.
1. Remove the electronics box cover by
unscrewing the 4 screws on each side.
2. Remove the two screw from the cover plate
and gently pull the plate away from the
electronics box. Leave the Drive Motor
cable connected to the board.
3. Insert the white plastic end of the pump
harness cable (from the back of the cabinet)
through the opening where the cover plate
was on the electronics box.
Summary of Contents for Stoelting Flavor Burst STL-80SS-DLX
Page 2: ......
Page 9: ...6 PAGE INTENTIONALLY LEFT BLANK ...
Page 11: ...8 General System Overview Figure 1 ...
Page 13: ...10 Outer Cabinet Continued Figure 2 ...
Page 15: ...12 Inner Cabinet Continued Figure 3 ...
Page 19: ...16 Syrup Pump and Related Parts Figure 5 ...
Page 21: ...18 Sanitizer Pump and Related Parts Figure 6 ...
Page 25: ...22 Spare Parts Kit Figure 8 ...
Page 26: ...23 PAGE INTENTIONALLY LEFT BLANK ...
Page 38: ...35 PAGE INTENTIONALLY LEFT BLANK ...
Page 70: ...67 PAGE INTENTIONALLY LEFT BLANK ...
Page 79: ......
Page 80: ......