WSR-D80112-S
Maintenance, Servicing and Inspection
8.5.2 Mounting
Remount the control magnet in reverse order as described in Chapter 8.5.1.
1. Ensure that the 74x3 O-ring is in its groove and is not damaged (Fig. 10).
2. Check that the four M6 threaded rods are screwed into the control housing (Fig.
10). If necessary, tighten them using water pump pliers.
3. Push the control magnet to the threaded rods.
4. Screw the four M6 hex. nuts including the four washers on the threaded rods and
tighten the same with a tightening torque of 7Nm.
5. Electrically connect the control magnet according to the customer's wiring
diagram, Chapter 10.
Fig. 10: Illustration of O-ring X
O-ring 74x3
M6 threaded rods
Summary of Contents for 22000106810