P118F Service Manual
TABLES & CHARTS
1/6/09
11-3
P118F SPECIFICATIONS, 380 Volt-3 Phase- 50Hz
Tube Size
inches
(cm)
1
(2.54)
1 1/4
(3.17)
1 1/2
(3.18)
Nominal Capacity
(1)
lbs/day
(Kg/day)
9,500
(4,309)
9,200
(4,173)
9,100
(4,128)
Overall Dimensions (LxWxH)
inches
(meters)
60 x 32 x 84
(1.5x0.81x2.1)
60 x 32 x 84
(1.5x0.81x2.1)
60 x 32 x 84
(1.5x0.81x2.1)
Shipping Weight
lbs
(Kg)
3200
(1452)
3200
(1452)
3200
(1452)
Operating Weight
lbs
(Kg)
2975
(1349)
2975
(1349)
2975
(1349)
Refrigerant Charge (HCFC-22)
lbs
(Kg)
260
(118)
260
(118)
260
(118)
Total FLA Water Cooled
(2)
37.9 37.9 37.9
Total FLA Air Cooled
(2)
42.4 42.4 42.4
Maximum Fuse
WC / AC
140/150 140/150 140/150
Minimum Ampacity
WC / AC
78/83 78/83 78/83
Water Requirements
-makeup
(3)
gpm
(m
3
/ Hr)
1.2
(0.27)
1.2
(0.27)
1.2
(0.27)
-condenser
(4)
gpm
(m
3
/ Hr)
37
(8.4)
37
(8.4)
37
(8.40)
Connection Sizes
-makeup water
FPT
3/4” 3/4” 3/4”
-tank drain
FPT
1” 1” 1”
-condenser water inlet
FPT
1 1/4”
1 1/4”
1 1/4”
-condenser water outlet
MPT
1 1/4”
1 1/4”
1 1/4”
-AC condenser inlet
ODC
1 5/8”
1 5/8”
1 5/8”
-AC condenser outlet
ODC
1 5/8”
1 5/8”
1 5/8”
Compressor -HP/KW/FLA
20 / 14.9 / 33.0
20 / 14.9 / 33.0
15 / 14.9 / 33.0
Water Pump -HP/KW/FLA
1.5 / 1.9 / 2.9
1.5 / 1.9 / 2.9
1.5 / 1.9 / 2.9
Cutter Motor -HP/KW/FLA
0.5 / 0.7 / 1.1
0.5 / 0.7 / 1.1
0.5 / 0.7 / 1.1
THR
Btu/hr
(kW)
170,000
(49.8)
170,000
(49.8)
170,000
(49.8)
Marley Cooling Tower
(5)
4821 4821 4821
-dimensions (LxWxH)
ft
(meters)
5x 4 x 6.5
(1.5x1.2x2.0)
5x 4 x 6.5
(1.5x1.2x2.0)
5x 4 x 6.5
(1.5x1.2x2.0)
-shipping weight
lbs
(Kg)
740
(336)
740
(336)
740
(336)
-operating weight
lbs
(Kg)
1340
(
608)
1340
(
608)
1340
(
608)
-fan (HP/KW/FLA)
1 / 0.8 / 3.6
1 / 0.8 / 3.6
1 / 0.8 / 3.6
Tower Pump
-flow
gpm
(m
3
/Hr)
78
(17.7)
78
(17.7)
78
(17.7)
-TDH
minimum
ft
(m)
80
(24.4)
80
(24.4)
80
(24.4)
-HP/KW/FLA
3 /2.2 / 9.6
3 /2.2 / 9.6
3 /2.2 / 9.6
-connections (inlet x outlet)
FPT
1.5” x 1”
1.5” x 1”
1.5” x 1”
-shipping weight
lbs
(Kg)
65
(29.5)
65
(29.5)
65
(29.5)
Kramer Air-Cooled Condenser
(6)
DD-361 DD-361 DD-361
- # of Fans / HP
5 / 0. 5
5 / 0. 5
5 / 0. 5
-total KW/FLA
2.8/4.5 2.8/4.5 2.8/4.5
-inlet connection
ODC
1 5/8”
1 5/8”
1 5/8”
-outlet connection
ODC
1 5/8”
1 5/8”
1 5/8”
-shipping weight
lbs
(Kg)
610
(277)
610
(277)
610
(277)
-operating weight
lbs
(Kg)
660
(299)
660
(299)
660
(299)
(1) Nominal capacity is based on 70°F makeup water, 100°F condensing temperature, 70°F ambient, and 0% blowdown.
(2) FLA for 200-volt models is approximately 2 times that of 380-volt models. Total FLA does not include cooling tower.
(3) Makeup water is maximum value and includes 10 gallons per cycle blowdown.
(4) Condenser flow rate is for 85°F entering water temperature and 100°F condensing.
(5) Tower sized for 85°F wet bulb temperature.
(6) Recommended air-cooled condenser is based on 15°F TD.
Vogt reserves the right to change designs and specifications without notice.
Table 11-2
Summary of Contents for TUBE-ICE P-118F
Page 1: ...P 118F TUBE ICE MACHINE Service Manual 5000 1 6 09 ...
Page 4: ......
Page 6: ......
Page 14: ...P118F Service Manual INTRODUCTION 1 6 09 1 4 FIGURE 1 1 Assembly Air Cooled Front View ...
Page 15: ...P118F Service Manual INTRODUCTION 1 6 09 1 5 FIGURE 1 2 Assembly Air Cooled Rear View ...
Page 16: ...P118F Service Manual INTRODUCTION 1 6 09 1 6 FIGURE 1 3 Assembly Air Cooled Right Side View ...
Page 17: ...P118F Service Manual INTRODUCTION 1 6 09 1 7 FIGURE 1 4 Assembly Water Cooled Front View ...
Page 18: ...P118F Service Manual INTRODUCTION 1 6 09 1 8 FIGURE 1 5 Assembly Water Cooled Rear View ...
Page 19: ...P118F Service Manual INTRODUCTION 1 6 09 1 9 FIGURE 1 6 Assembly Water Cooled Right Side View ...
Page 20: ...P118F Service Manual INTRODUCTION 1 6 09 1 10 ...
Page 23: ...P118F Service Manual RECEIPT OF YOUR TUBE ICE MACHINE 1 6 09 2 3 ...
Page 37: ......
Page 38: ...1 6 09 ...
Page 48: ......
Page 49: ...1 6 09 ...
Page 88: ...P118F Service Manual SERVICE OPERATIONS 1 6 09 9 18 FIGURE 9 8 Cutter Water Tank Assembly ...
Page 89: ...P118F Service Manual SERVICE OPERATIONS 1 6 09 9 19 FIGURE 9 9 Cutter Tank Parts cylinder ice ...
Page 90: ...P118F Service Manual SERVICE OPERATIONS 1 6 09 9 20 FIGURE 9 10 Cutter Drive Parts ...
Page 102: ...P118F Service Manual TABLES CHARTS 1 6 09 11 1 11 Tables Charts ...
Page 111: ...P118F Service Manual TABLES CHARTS 1 6 09 11 10 ...