P118F Service Manual
TABLES & CHARTS
1/6/09
11-2
P118F SPECIFICATIONS, 208-230 Volt-3 Phase- 60Hz
Tube Size
inches
(cm)
1
(2.54)
1 1/4
(3.17)
1 1/2
(3.18)
Nominal Capacity
(1)
lbs/day
(Kg/day)
10,400
(4,717)
9,800
(4,445)
9,700
(4,400)
Overall Dimensions (LxWxH)
inches
(meters)
60 x 32 x 84
(1.5x0.81x2.1)
60 x 32 x 84
(1.5x0.81x2.1)
60 x 32 x 84
(1.5x0.81x2.1)
Shipping Weight
lbs
(Kg)
3200
(1452)
3200
(1452)
3200
(1452)
Operating Weight
lbs
(Kg)
2975
(1349)
2975
(1349)
2975
(1349)
Refrigerant Charge (HCFC-22)
lbs
(Kg)
260
(118)
260
(118)
260
(118)
Total FLA Water Cooled
(2)
82.3 82.3 82.3
Total FLA Air Cooled
(2)
73.3 73.3 73.3
Maximum Fuse
WC / AC
120/130 120/130 120/130
Minimum Ampacity
WC / AC
68/77 68/77 68/77
Water Requirements
-makeup
(3)
gpm
(m
3
/ Hr)
1.2
(0.27)
1.2
(0.27)
1.2
(0.27)
-condenser
(4)
gpm
(m
3
/ Hr)
37
(8.40)
37
(8.40)
37
(8.40)
Connection Sizes
-makeup water
FPT
3/4” ¾” 3/4”
-tank drain
FPT
1” 1” 1”
-condenser water inlet
FPT
1 1/4”
1 1/4”
1 1/4”
-condenser water outlet
MPT
1 1/4”
1 1/4”
1 1/4”
-AC condenser inlet
ODC
1 5/8”
1 5/8”
1 5/8”
-AC condenser outlet
ODC
1 1/8”
1 1/8”
1 1/8”
Compressor -HP/KW/FLA
15/11.2/59.6 15/11.2/59.6 15/11.2/59.6
Water Pump -HP/KW/FLA
1.5 / 1.9 / 4.8
1.5 / 1.9 / 4.8
1.5 / 1.9 / 4.8
Cutter Motor -HP/KW/FLA
0.5 / 0.7 / 2.2
0.5 / 0.7 / 2.2
0.5 / 0.7 / 2.2
THR
Btu/hr
(kW)
170,000
(49.8)
170,000
(49.8)
170,000
(49.8)
Marley Cooling Tower
(5)
4821 4821 4821
-dimensions (LxWxH)
ft
(meters)
5x 4 x 6.5
(1.5x1.2x2.0)
5x 4 x 6.5
(1.5x1.2x2.0)
5x 4 x 6.5
(1.5x1.2x2.0)
-shipping weight
lbs
(Kg)
740
(336)
740
(336)
740
(336)
-operating weight
lbs
(Kg)
1340
(
608)
1340
(
608)
1340
(
608)
-fan (HP/KW/FLA)
1 / 0.8 / 3.6
1 / 0.8 / 3.6
1 / 0.8 / 3.6
Tower Pump
-flow
gpm
(m
3
/Hr)
78
(17.7)
78
(17.7)
78
(17.7)
-TDH
minimum
ft
(m)
80
(24.4)
80
(24.4)
80
(24.4)
-HP/KW/FLA
3 /2.2 / 9.6
3 /2.2 / 9.6
3 /2.2 / 9.6
-connections (inlet x outlet)
FPT
1.5” x 1”
1.5” x 1”
1.5” x 1”
-shipping weight
lbs
(Kg)
65
(29.5)
65
(29.5)
65
(29.5)
Kramer Air-Cooled Condenser
(6)
DD-311 DD-311 DD-311
- # of Fans / HP
5 / 0.5
5 / 0.5
5 / 0.5
-total KW/FLA
2.8/ 9.0
2.8 / 9.0
2.8 / 9.0
-inlet connection
ODC
1 5/8”
1 5/8”
1 5/8”
-outlet connection
ODC
1 1/8”
1 1/8”
1 1/8”
-shipping weight
lbs
(Kg)
610
(277)
610
(277)
610
(277)
-operating weight
lbs
(Kg)
660
(299)
660
(299)
660
(299)
(1) Nominal capacity is based on 70°F makeup water, 100°F condensing temperature, 70°F ambient, and 0% blowdown.
(2) FLA for 460 volt models is approximately 1/2 that of 230 volt models. Total FLA does not include cooling tower.
(3) Makeup water is maximum value and includes 10 gallons per cycle blowdown.
(4) Condenser flow rate is for 85°F entering water temperature and 100°F condensing.
(5) Tower sized for 85°F wet bulb temperature.
(6) Recommended air-cooled condenser is based on 15°F TD.
Vogt reserves the right to change designs and specifications without notice.
Table 11-1
Summary of Contents for TUBE-ICE P-118F
Page 1: ...P 118F TUBE ICE MACHINE Service Manual 5000 1 6 09 ...
Page 4: ......
Page 6: ......
Page 14: ...P118F Service Manual INTRODUCTION 1 6 09 1 4 FIGURE 1 1 Assembly Air Cooled Front View ...
Page 15: ...P118F Service Manual INTRODUCTION 1 6 09 1 5 FIGURE 1 2 Assembly Air Cooled Rear View ...
Page 16: ...P118F Service Manual INTRODUCTION 1 6 09 1 6 FIGURE 1 3 Assembly Air Cooled Right Side View ...
Page 17: ...P118F Service Manual INTRODUCTION 1 6 09 1 7 FIGURE 1 4 Assembly Water Cooled Front View ...
Page 18: ...P118F Service Manual INTRODUCTION 1 6 09 1 8 FIGURE 1 5 Assembly Water Cooled Rear View ...
Page 19: ...P118F Service Manual INTRODUCTION 1 6 09 1 9 FIGURE 1 6 Assembly Water Cooled Right Side View ...
Page 20: ...P118F Service Manual INTRODUCTION 1 6 09 1 10 ...
Page 23: ...P118F Service Manual RECEIPT OF YOUR TUBE ICE MACHINE 1 6 09 2 3 ...
Page 37: ......
Page 38: ...1 6 09 ...
Page 48: ......
Page 49: ...1 6 09 ...
Page 88: ...P118F Service Manual SERVICE OPERATIONS 1 6 09 9 18 FIGURE 9 8 Cutter Water Tank Assembly ...
Page 89: ...P118F Service Manual SERVICE OPERATIONS 1 6 09 9 19 FIGURE 9 9 Cutter Tank Parts cylinder ice ...
Page 90: ...P118F Service Manual SERVICE OPERATIONS 1 6 09 9 20 FIGURE 9 10 Cutter Drive Parts ...
Page 102: ...P118F Service Manual TABLES CHARTS 1 6 09 11 1 11 Tables Charts ...
Page 111: ...P118F Service Manual TABLES CHARTS 1 6 09 11 10 ...