05TA Service Manual
OPTIONS AND ACCESSORIES
8/13/01
10-10
From the set up screen two additional screens can be displayed by pressing “B” on the operator
interface. These two screens are refereed to as monitor screens. The first screen displays the cycles
and lbs of ice produced since the operator has reset the counter. The screen is shown below.
B = NEXT SCREEN
A = RESET
##### CYCLES
####### LBS ICE
Pressing “A” from this screen will reset the cycle count and pounds of ice produced to zero. This will
not reset the total cycles displayed on the main set up screen.
Pressing “B” from this screen will call the second monitor screen. The second monitor screen
displays the previous total cycle time, lbs of ice produced per cycle and lbs of ice produced per day
based on the last cycle time. The screen is shown below.
C=SET-UP SCRN
ICE/DAY #####LBS
PREV CYCLE ##:##
ICE/CYCLE ###LBS
The user can set the pounds of ice per cycle from this screen. The capacities and ice production totals
calculated on these two screens are based on the user input number for pounds of ice per cycle. This
depends on how thick the ice is and how the machine is set up. For best results, the number used
here should be the average actual measured weight from two or more consecutive cycles.
PLC (Programmable Logic Controller)
Summary of Contents for TUBE-ICE 05TA
Page 4: ...Vogt Tube Ice Machines Installation Service Manual and Parts Catalog 12A4171M06 05TA Model ...
Page 82: ...05TA Service Manual SERVICE OPERATIONS 8 13 01 9 18 FIGURE 9 10 Cutter Drive Parts ...
Page 95: ...05TA Service Manual OPTIONS AND ACCESSORIES 8 13 01 10 11 FIGURE 10 3 Control Panel Parts ...
Page 97: ...05TA Service Manual OPTIONS AND ACCESSORIES 8 13 01 10 13 FIGURE 10 4 Wiring Schematic ...
Page 103: ...05TA Service Manual TABLES CHARTS 8 14 01 11 1 11 Tables Charts ...