05TA Service Manual
INSTALLING YOUR TUBE-ICE
®
MACHINE
8/13/01
3-4
Wiring and Electrical Connection
! WARNING !
Only service personnel experienced in refrigeration and qualified to work with high voltage
electrical equipment should be allowed to install or work on the Tube-Ice
®
machine.
! WARNING !
Refer to TABLE 3-2 below to properly size wiring connections. A fused disconnect must be
provided near the Tube-Ice
®
machine. Connect 3 phase power to terminals L1, L2, L3 for operation
of the Tube-Ice
®
machine and its controls. Rotation checking of cutter motor and water pump is
required (see following section). Also, if one leg of the 3 phase power is higher or lower (“Wild”),
then it should be connected to terminal #L2. Connect the “Ground” wire to the “Ground” lug
provided.
FIGURE 3-3
Control Panel Power Connections
Water Cooled
Air Cooled
Standard Voltages
F.L.A.
Min. Ampacity Max. Fuse
F.L.A.
Min. Ampacity
Max. Fuse
208/230, 3ph, 60 Hz
66.9
81.8
145
76.9
91.8
155
460, 3ph, 60 Hz
32.7
39.9
70
37.2
44.4
75
220, 3ph, 50 Hz
73.3
89.8
160
83.3
99.8
170
400, 3ph, 50 Hz
37.2
45.4
80
42.2
50.4
85
TABLE 3-2
Electrical Specifications
Summary of Contents for TUBE-ICE 05TA
Page 4: ...Vogt Tube Ice Machines Installation Service Manual and Parts Catalog 12A4171M06 05TA Model ...
Page 82: ...05TA Service Manual SERVICE OPERATIONS 8 13 01 9 18 FIGURE 9 10 Cutter Drive Parts ...
Page 95: ...05TA Service Manual OPTIONS AND ACCESSORIES 8 13 01 10 11 FIGURE 10 3 Control Panel Parts ...
Page 97: ...05TA Service Manual OPTIONS AND ACCESSORIES 8 13 01 10 13 FIGURE 10 4 Wiring Schematic ...
Page 103: ...05TA Service Manual TABLES CHARTS 8 14 01 11 1 11 Tables Charts ...